Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in November 2026. The most recent job was on November 10, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Responded to a no-heat call on the furnace and inspected the unit's electrical compartment, including the sequencer relays, limit switches, terminal block, and associated low- and line-voltage wiring, to diagnose the loss of warm air. Wiring was found cluttered and unevenly routed with light discoloration and dust present, and the unit's access panel was verified secure with no visible damage, frost, or anomalies.
Performed scheduled cooling tune-up on the Daikin system, inspecting the blower assembly and noting dust and grime buildup on the squirrel-cage blades along with minor rust staining at the housing, and verified thermostat operation. Thermostat was found in Em Heat with the fan set to Auto, and the previously noted condenser coil leak (treated with stop leak) remains a concern requiring monitoring for refrigerant loss.
Performed a monthly basic heating inspection on the Daikin-controlled system, verifying thermostat operation on its programmed schedule at a 67°F reading with 52% indoor humidity. Inspected the air handler and replaced the 20x20x4 high-performance pleated filter, confirming proper seating in the filter slot, and checked the foil-faced insulated supply ductwork, including a previously taped section, for integrity.
Performed a scheduled heating tune-up on an 11-year-old high-efficiency gas furnace, including inspection of the cabinet and operating components, with no visible damage, rust, or frost found. Verified thermostat operation in heat mode with fan set to auto, and installed a new 20x25x4 pleated air filter, marked with the replacement date for future reference. Furnace is operating properly and ready for the heating season.
Returned to complete the previously sold repair on the vertical water-source heat pump. Performed the remaining repair work, restored the unit to operation, and verified proper system function. Inspected the unit, electrical connections, and condensate/water piping and found no frost, ice, or significant rust present.
Performed a clean and check on the gas furnace, including a combustion analysis with a Bacharach analyzer that measured 8.6% O2 and 42 ppm CO in natural gas mode, and inspected the system's 16x25x4 air filter. The thermostat displayed a low-battery warning, so replacement batteries are recommended. The filter replacement was discussed with the homeowner, with pricing to be provided before any replacement is made.
Responded to a heat pump fault on a Bryant system displaying error code 86-46 (VFD System Lockout – Communication), with event history showing a preceding 86-06 VFD communication fault. Verified the unit was still operating and documented the fault codes and system event log via the thermostat.
Note: The details provided do not indicate any repair, corrective action, or maintenance performed, so none is reported here. Please supply the work completed (e.g., VFD communication wiring/connection checks, board inspection or replacement, maintenance tasks) so the record can be finalized accurately.
Performed seasonal heating maintenance on two HVAC systems under the Basic maintenance plan. Inspected the blower assembly and wheel, then replaced the dirty 4-inch pleated return air filter and verified proper airflow direction, with the washable 16x24x1 filter serviced as listed. Systems were operated and confirmed functioning properly.
Performed routine AC tune-up on a split system installed in 2024, with no problems reported and the system operating properly. Inspected and tested the cooling system components, including the outdoor unit, and verified overall system performance, with a combustion analyzer used on the furnace flue to confirm safe operation. No deficiencies were found; the customer will address separate AC concerns with a comfort advisor during an upcoming water heater estimate.
Responded to a continuously running blower complaint on an approximately 15-year-old natural gas furnace and inspected the furnace cabinet, installed 14x25x1 pleated air filter, and wall thermostat. Verified the thermostat fan switch position and "Filter" indicator, and found the filter relatively clean with no restriction affecting airflow. Further diagnostics of the fan control circuit and blower relay are recommended to fully resolve the continuous blower operation.
Installed a warranty replacement air handler with a downflow conversion kit and verified proper operation, with a handheld thermometer used to confirm supply air temperature during startup. The customer received a signed completion certificate upon job completion, and all removed equipment, materials, and tools were returned to the warehouse.
Responded to a newly installed furnace displaying a fault code on the control panel upon startup. Inspected the control cabinet and wiring harness, verifying connections at the terminal block and wire connectors, with no visible damage, corrosion, or loose connections observed. Further diagnostics are needed to identify the cause of the error code.
Performed scheduled monthly heating maintenance inspection on the system, verifying operation and recording temperature readings with a calibrated UEi PDT650 pocket thermometer (72.8°F) and handheld digital meter. Monitored system performance and conditions to confirm proper heating function; filter replacement was not included in this visit. System operating within normal parameters at completion.
Performed a seasonal heating maintenance inspection on the Lennox EL280UH(X)E gas furnace, verifying proper operation and checking the system with test instrumentation. Noted moisture and frost/mineral residue on the flexible supply duct and plenum, along with white powdery deposits on the adjacent water heater and floor, and recommend further evaluation of condensation and moisture sources. Updated the maintenance and repair history card on the unit; customer to supply the 20x25x4 filter, which was not included.
Inspected the existing washing machine outlet box and found damaged drywall at the opening, corroded drain fittings, and signs of moisture and debris in the lower wall cavity. Documented the conditions with photos and determined that the box requires replacement; a return visit is required to install a new laundry box.
Installed a complete Lennox split system for the upstairs, consisting of an 80% AFUE gas furnace with matching evaporator coil and an outdoor air conditioning condenser. Set the furnace and coil in the utility closet, connected the supply and return plenum and ductwork, flue venting, gas supply with shutoff valve, and condensate drain. Mounted the condenser at the exterior wall and connected the refrigerant line set and electrical disconnect, completing the system for operation.
Performed scheduled monthly heating maintenance, inspecting the outdoor condenser unit and verifying the Lennox thermostat configuration. The condenser cabinet, louvered panels, and fan grille were found clean and free of frost, rust, or damage, with the unit level on its pad and clear of debris. The thermostat was confirmed in heat mode with a 70° setpoint, indoor temperature of 74°, and 53% relative humidity, and the system responded normally to the call for heat. The 20x20x4 filter was not included in this visit.
Performed seasonal heating maintenance inspection, including a supply duct temperature check (65.1°F measured with a handheld thermometer) and visual inspection of the blower wheel, which was clean with no debris, rust, or cracks. Furnace cabinet, ductwork, and control components were intact with no signs of damage, and system operation was found satisfactory. The 20x25x4 filter was not included in the visit and is to be supplied separately.
Responded to a no-heat complaint on a gas furnace and verified thermostat operation, which showed a heat call (Heat On) with a 76° setpoint against 71° ambient. Inspected the furnace with the access panel removed and observed the control and wiring assemblies and ignition sequence, with a diagnostic monitoring device attached to the cabinet to evaluate system operation.
Performed scheduled monthly heating maintenance and replaced the heavily loaded 16x25x1 pleated return-air filter, which showed significant dust and debris accumulation. Verified thermostat operation in heat mode with fan set to auto, confirming the system responded to a 71°F setpoint; noted a warning indicator on the thermostat display for follow-up monitoring.