Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in November 2026. The most recent job was on November 24, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Performed diagnostic evaluation of a wall-recessed furnace with a non-responsive thermostat following a recent thermostat replacement. Removed the front access panel and inspected the control wiring, blower assembly, burner/gas valve area, and the electrical section, including the 45+5 µF, 440VAC dual-run capacitor and contactor, verifying wiring connections and component condition as part of troubleshooting the loss of thermostat operation.
Performed seasonal heating maintenance, replacing the 16x25x1 pleated return air filter and verifying furnace combustion performance with a calibrated combustion analyzer. Flue gas readings showed O2 at 12.7%, CO2 at 4.7%, and CO at 24 ppm, with a stack temperature of 135.1°F, confirming the appliance is operating safely within normal parameters.
Performed a second-opinion diagnostic on a furnace installed in 2011, evaluating a previously diagnosed failed blower motor. Inspected the blower compartment and found the motor terminal block and wiring heavily contaminated with dust, lint, and debris, with exposed conductor ends at the terminals. Reviewed repair options for the blower motor and discussed available financing.
Performed scheduled heating system maintenance on the Daikin vertical air handler, including inspection of the cabinet, supply ductwork, refrigerant line set, wiring, and PVC condensate drain assembly. Verified air temperature with a digital pocket thermometer (68.5°F reading) and observed no visible frost, rust, or damage; filter replacement was not part of this visit.
Performed a second-opinion diagnostic evaluation on a Trane XE 80 gas furnace following a reported heating cycle irregularity, where the unit appeared to run longer than expected and immediately re-entered a call-for-heat sequence after cycling off. Observed the furnace operating sequence, including the blower off-delay period and the brief fan glitch occurring prior to shutdown, to evaluate control board and thermostat call-for-heat behavior.
Diagnosed a geothermal heat pump system that would not call for heat unless the contactor was manually engaged. Verified the thermostat was calling for electric/auxiliary heat with the fan running and checked supply air temperature at 135.6°F during operation. Repair was completed on the faulty contactor to restore normal heating call operation.
Performed scheduled heating system maintenance, inspecting the gas burner assembly and observing a stable blue flame during operation. Used a true RMS clamp meter to take electrical measurements on the furnace while it ran, and verified the thermostat was operating correctly in Auto Heat mode with the set point matched to room temperature. Visually checked the wiring and connections, blower and inducer components, and cabinet interior; no damage, corrosion, or abnormal conditions were found.
Replaced the existing bath exhaust fan, reconnecting the flexible insulated foil duct run through the attic to the roof vent stack and verifying the exhaust path was secure for proper discharge. Restored the work area and confirmed the unit operated correctly upon completion.
Responded to a no-heat complaint on a Lennox gas furnace with an unresponsive wall thermostat. Inspected the thermostat, which displayed a 57° room temperature against a 75° heat setpoint in heat-only mode without calling for heat, and verified the furnace, gas supply valve, condensate drain, and refrigerant line connections showed no visible damage, rust, or leaks.
Performed monthly heating maintenance on the gas furnace, verifying electrical operation with a true-RMS clamp meter on the control wiring and measuring a supply air temperature of approximately 116.7°F at the ceiling diffuser to confirm proper heat output. Inspected the unit and surrounding area, noting no visible damage at the supply diffuser, and the system was operating normally at completion.
Performed routine maintenance tune-up on a 17-year-old Payne gas heating system, including combustion analysis with a Bacharach analyzer that measured Oâ‚‚ at 9.4% and CO at 20 ppm in natural gas run mode. Electrical testing was also performed with a true RMS multimeter, and the system was confirmed operational with no issues reported.
Inspected the attic-installed air handler and associated refrigerant line set where a roofing nail had penetrated the line, and documented the damaged section and surrounding insulated copper/black suction line connections for repair evaluation. Prepared an estimate for repairing the punctured furnace line.
Installed a new Lennox outdoor condenser on a composite pad with a gravel base, run with an insulated refrigerant line set and a wall-mounted electrical disconnect connected to the exterior service panel. The unit was left clean and undamaged. Cut an opening in the drywall for the supply register and ductwork connection, with a louvered vent cover mounted above it.
Performed scheduled heating maintenance on the Daikin heat pump system, including inspection of the wall-mounted digital thermostat, which was clean, intact, and operating normally at a 66°F reading with 49% indoor humidity. Inspected the air handler blower compartment and found dust and grime accumulation on the blower wheel surfaces and compartment insulation, with low-voltage control wiring and terminal connections observed secure.
Responded to a no-heat call on a gas furnace where the blower failed to deliver heat and ran continuously. Inspection of the blower assembly revealed heavy dust and lint buildup on the squirrel-cage blower wheel, restricting airflow, and the return air filter was dirty. Documented findings and conditions with photos.
Reattached the disconnected flexible duct run serving the back left bedroom and secured it to restore proper airflow. Replaced a 12-inch flexible duct section running from the living room supply to the plenum, ensuring a sealed, properly supported connection within the attic insulation.
Responded to a low water pressure complaint and refilled the water softener brine tank with salt. Documented moisture, beaded droplets, and discolored residue on an adjacent interior surface, indicating possible leakage or condensation.
Returned to the site to install the loop conditioner on the system's piping as required. Inspected the existing insulated supply/return line and its pressure gauge, which read approximately 40 psi, and noted worn, flaking foam insulation and staining at the base of the piping that should be monitored.
Responded to an emergency burst pipe at the boiler recirculation circulator, which was discharging water into the basement after the main water supply had been shut off. Located the failed section at the circulator pump piping within the wall cavity, repaired the damaged pipe and fittings, and secured the connections with clamps. Restored water service to the home.
Performed seasonal heating maintenance and inspected the air handler cabinet and evaporator coil assembly, noting condensation on the cabinet surfaces and staining and rust discoloration on the bottom pan. Verified system air temperature with a digital thermometer (74.1°F reading) and confirmed proper illumination and access for inspection of the coil, copper tubing, and filter drier connections.