Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in November 2026. The most recent job was on November 19, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Inspected the reported sump pump discharge leak and the dripping pressure regulator on the main water supply line. Examination of the basement piping showed a brass backflow preventer assembly with isolation ball valves, test cocks, and a union fitting, with no visible leaks, frost, or heavy corrosion at the assembly. Some tarnishing and discoloration was noted on the aged brass fittings and adjacent pipe segment.
Performed scheduled heating-season maintenance on the Carrier air handler and associated system. Inspected the air handler cabinet, condensate drain piping, insulated refrigerant line set, and filter cabinet, with no visible damage or abnormal conditions observed. Verified thermostat operation, which displayed a 72°F actual temperature with a "check filter" alert active, indicating the filter is due for replacement.
Responded to a no-heat call on a dual-fuel system where the thermostat was calling for emergency heat instead of heat pump operation and the gas furnace was not energizing. Inspected the outdoor heat pump unit, which had leaf and debris accumulation around the base and coil guard, and checked the thermostat settings and programming. Diagnostic findings were not documented, so the root cause and any repair performed could not be confirmed from the available records.
Responded to a no-heat call on a gas furnace approximately 10 years old and inspected the unit's control compartment, wiring, gas valve, and flue assembly, noting dust and grime buildup around the cabinet. Verified thermostat operation, which was set to heat and displaying a room temperature of 64 degrees, to assist in diagnosing the call-for-heat issue.
Performed scheduled heating system maintenance, including replacement of the 20x20x4 media air filter. Verified thermostat operation, with the Daikin controller reading 69°F indoor against a 77°F setpoint, and checked supply air temperature at the ductwork with a digital pocket thermometer, measuring 74.4°F.
Performed scheduled monthly maintenance on the closed-loop geothermal heating system, including a 14x30x1 air filter service. Verified the Geo-Flo loop pressure at approximately 20 PSI and checked the loop fittings for leaks. Noted for future fall visits that the domestic hot water function will be disabled to reduce load on the system and keep heat within the geothermal section.
Performed seasonal heating system maintenance and supplied a new 20x25x4 pleated media filter for installation. Used a digital thermometer to verify air temperature at the ductwork, and noted rust staining at a galvanized duct seam and debris buildup on adjacent framing in the enclosed equipment space.
Performed seasonal heating maintenance on two systems, inspecting the air handler plenum and ductwork interior, including foil-taped seams, panel joints, and coil/filter surfaces, and noting light dust accumulation and a minor rust spot on a metal flange. Verified airflow temperature with a digital pocket thermometer (69.8°F) as part of system performance checks.
Replaced the existing Honeywell Home dial-type thermostat with a new unit. Removed the old thermostat from the wall, disconnected the low-voltage control wiring, and installed the replacement. The new thermostat was inspected and found clean and intact, with no visible damage, frost, or rust.
Responded to a complaint of reduced flow at the kitchen faucet. Replaced the faucet aerator, which did not resolve the low flow, and verified operation by running water through the gooseneck spout into the sink basin, confirming a steady stream at the spout tip. Further diagnosis of the supply side or internal faucet components may be needed to fully restore flow.
Performed monthly heating system maintenance, verifying thermostat operation in heat mode with a 68°F setpoint and checking supply air temperature at a floor register, which measured 115.8°F, confirming proper heat output. Observed dust buildup on the register slats; no damage or abnormal operating conditions were noted.
Responded to a no-heat complaint on the furnace and performed a diagnostic inspection of the unit and its access area. Observed heavy rust and corrosion along the cabinet panel seam with a visible gap, along with significant dust, lint, and debris buildup on the surrounding components, wire insulation, and fittings. Findings were documented, and repair approval was pending at the time of service.
Performed scheduled heating maintenance tune-up on a 9-year-old furnace, including inspection of the blower assembly and ECM motor controller. The blower wheel showed an even layer of dust and residue on the blades with no cracks or damage, and the controller housing and associated wiring harness were inspected with connections found intact.
Flushed the hydronic boiler loop serving the radiant floor heating system using a submersible pump and hose circulation setup, with discolored, sediment-laden return fluid indicating contaminant removal from the system. Verified the Honeywell ProSeries digital thermostat is mounted and operating to control the heating zone.
Responded to a no-heat call on a newly installed Lennox vertical furnace reporting an ignition failure lockout. Inspected the gas valve assembly, gas piping connections, and wiring harness, and verified the unit is properly vented and powered in the utility closet installation.
Performed annual heating system maintenance, including inspection of the blower assembly, which was found clean and intact with no rust, frost, or damage to the blower wheel, motor shaft, or housing. Verified thermostat operation in heat mode with the fan set to auto and the setpoint holding at 70°F, with the display reading normal and no abnormal conditions observed.
Responded to a reported furnace issue with the system showing an idle status despite an active heat call. Inspected the thermostat, which indicated a heat call with a 72° setpoint against a 61° indoor temperature, and noted a network-offline condition and physical chipping on the thermostat casing. Evaluated the furnace's response to the heat demand and verified the system operating on a heat call at a raised setpoint, with indoor temperature rising to 75° and the thermostat displaying "Heat On."
Returned to the site to pump down and evacuate the refrigerant system, and re-leveled the outdoor condenser pad. Verified the condenser sits level using a spirit level across the top of the unit, with no frost, ice, rust, or cracks observed. Also assessed the home for a duct cleaning estimate.
Performed monthly heating system maintenance, including combustion analysis of the appliance flue gases (readings recorded: O2 9.7%, CO 13 ppm, CO2 6.4%, stack temperature 96.8°F). Inspected the blower assembly and found a light accumulation of dust and lint on the squirrel-cage wheel blades and housing.