At Reliable Comfort, we’ve been serving the good people of Southern Indiana since 2001, ensuring you have that peace of mind around the clock and in every room of your house. As a family-operated business, we believe in transparency, so we have a 100% satisfaction guarantee. Looking to save a bit? Check out our discounts and financing options — we’ve got your back!
Need HVAC, plumbing, or generator repairs in Southern Indiana? Schedule an appointment or call our licensed experts at (812) 200-0786 today.
Top-Rated HVAC
In Southern Indiana, it isn’t unusual to have your heater on in the morning, flip to air conditioning during the day, and turn it back on at night! Our crazy weather makes having a working HVAC system so important. Whether it’s your furnace or your AC unit, we’ll take care of all your HVAC repairs, replacements, and maintenance.
Heating
- Heating installation: New home? Upgrading? We’ve got your heating solutions. From furnace installation to geothermal heating, our team ensures perfect warmth.
- Heating repair: Whether it’s a furnace repair or heat pump repair, we ensure your heating units are back up and running in no time.
- Heating maintenance: From furnace maintenance to boiler tune-ups, we’ll keep your heating systems performing their best. Join the Comfort Club for even better maintenance deals!
Cooling
- Air conditioning installation: Stay cool with our top-tier air conditioning installation services. Whether it’s a traditional unit or a geothermal system, we got you covered.
- Air conditioning repair: From common hiccups to complex problems, our team is adept at air conditioning repair.
- Air conditioning maintenance: Regular air conditioning maintenance can prolong your unit’s life and save on energy bills. Let us help.
Professional Plumbing
A minor leak can cause immense water damage in a short amount of time, so it’s vital to call a plumber like Reliable Comfort right away. We provide plumbing services, like replacing a burst pipe or fixing a leaky faucet, which can be serious issues if ignored. We also repair gas lines and maintain your drains and pipes so that they flow smoothly.
Got a sump pump? We’ll help you keep it running so you don’t have to worry about a flooded basement. Or if you’re ready to improve your water quality and safety, we can install refreshing water filtration solutions in your home.
Generators
Ever experienced a sudden blackout and wished you were better prepared? With our whole-home standby generators, you won’t have to worry about unexpected power outages or rolling brownouts or blackouts. These generators seamlessly kick in, ensuring your home remains powered and your daily routine undisturbed. It’s not just about convenience; it’s about providing peace of mind for your family.
Considering a generator for your home? Contact Reliable Comfort at (812) 200-0786 for a detailed consultation today.
Why Choose Reliable Comfort?
Here’s the simple truth: You’re not just getting a service with Reliable Comfort. You’re joining a family that cares. With our 100% satisfaction guarantee, your home’s comfort is in trusted hands.
Ready to upgrade your HVAC or plumbing system? Call the Reliable Comfort team at (812) 200-0786 for a no-obligation consultation.
FAQ
What is the average life expectancy of equipment?
Most systems have a lifetime of 10 to 20 years. As your equipment gets older, its efficiency can decrease dramatically. You may notice that it gets noisier and needs repairs more often. When a unit begins to show it’s age, you have two choices. You can overhaul the system or replace it. Because heating and cooling technologies improve over time, a new system designed with newer, more energy-efficient equipment makes sense, especially if your system is 10 or more years old. We can estimate the cost of a new system as well as a payback schedule that will show you how newer technology will pay you back in lower energy usage.
Why should I purchase a service agreement?
Without warranty coverage, a breakdown can mean significant expense in parts, labor, or both. However, with one of our service agreements, you avoid that unexpected significant expense. While no warranty can guard against every possible problem, we can explain the broad range of protection our service agreements afford.
Why should I buy Energy Star labeled equipment?
The average home spends about $1,900 annually on energy bills. Heating and cooling accounts for as much as half of a home’s energy use. The EPA provides important recommendations for energy-efficient equipment, including proper sizing, quality installation and maintenance, and other home improvement considerations to help you get the most out of the heating and cooling products you purchase, save energy, and save as much as 20% annually on your total energy costs.
ENERGY STAR qualified products prevent greenhouse gas emissions by meeting strict energy efficiency guidelines set by the U.S. Environmental Protection Agency and the U.S. Department of Energy.
What does the Energy Factor (EF) on my water heater mean?
The water heater Energy Factor is a measure of the overall efficiency of the water heater. This is determined by comparing the energy in the heated water used daily to the total daily energy consumption of the water heater. The EF can be used to compare the energy efficiency of water heaters. Water heaters with higher EFs will have lower annual operating costs than comparable models with lower EFs. A higher EF signifies a more efficient model. Water heaters with high EF ratings may cost more initially, but save energy and money in the long run. Eventually, they will pay for themselves through a lifetime of energy savings.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Seymour, IN in September 2026. The most recent job was on September 6, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 1,733 jobs in Seymour, IN in the last 12 months.Recent Jobs and Reviews in Seymour, IN
Seymour, IN at a glance
Job Locations and Reviews
Responded to customer inquiry regarding HVAC system operation and thermostat functionality. Inspected residential heating system including digital programmable thermostat currently set at 70°F and basement-mounted furnace with associated ductwork, condensate drain lines, and electrical connections. Documented system configuration with photos showing thermostat display and complete furnace installation including flexible and rigid ductwork, PVC drainage piping, and proper electrical wiring. Addressed customer questions about system operation and provided technical guidance on equipment functionality.
Conducted estimate for replacement of existing 2007 R22 heat pump cooling system that experienced operational failure over the weekend but was currently functioning at time of visit. Performed thorough assessment of aging equipment, documented measurements and physical condition of existing unit showing significant weathering and deterioration of exterior surfaces with rust staining and paint degradation. Customer proactively seeking replacement options due to system age, obsolete R22 refrigerant, and recent performance issues.
Responded to customer inquiry regarding electric storage tank water heater in basement utility area. Conducted visual inspection of unit, documented current condition with photographs showing manufacturer specification label, copper piping connections, and mounting components. Water heater appears to be in normal operating condition with no visible signs of damage, corrosion, or leaks. Answered customer questions and provided technical information as requested.
Completed routine monthly HVAC maintenance visit including cooling and heating system inspection. Verified Bryant programmable thermostat operation at 78°F in cooling mode, inspected outdoor condenser unit for proper operation and clearance, and documented equipment conditions. Filter size remains to be determined for future service visits.
# HVAC Maintenance - Cooling System Service
Completed basic monthly preventive maintenance on residential cooling system. Performed refrigerant pressure diagnostics using manifold gauge set at the outdoor condenser unit, verifying system charge levels and operational parameters across both high and low-side pressures. Inspected electrical components within the condensing unit, including capacitor connections, control board terminals, and associated wiring harnesses to ensure proper electrical integrity and safe operation. All condenser coil fins were found in clean condition with adequate airflow. System operational checks confirmed unit is functioning within normal parameters.
Responded to service call for non-operational air conditioning system with frozen evaporator coil following routine maintenance visit. Upon arrival, confirmed Goodman HVAC system had experienced freeze-up condition overnight. Allowed sufficient time for complete ice thaw on evaporator coil before diagnostic testing. Inspected air filter and found restriction causing reduced airflow across coil. Replaced dirty air filter with proper size filter to restore adequate system airflow. Verified thermostat operation and confirmed unit set to cooling mode at 73°F with current room temperature reading 77°F. Checked refrigerant pressures after thaw cycle completed and found levels within manufacturer specifications. Tested blower motor operation and confirmed proper CFM delivery through supply ductwork. Cycled system through complete cooling cycle and monitored for proper operation without re-freezing. Educated customer on importance of regular filter changes to prevent future freeze-up condition
Responded to no-cooling call with thermostat displaying "trying to start" message and unresponsive controls. Performed diagnostic troubleshooting on air conditioning system and condensing unit. System inspected and issue resolved, restoring normal thermostat operation and cooling functionality.
Responded to service urgent alert on thermostat with no airflow and temperature differential of 7 degrees (set at 75°F, actual 82°F). Inspected outdoor condensing unit and indoor air handler to diagnose complete system failure. Identified and resolved issue preventing air circulation, restoring proper system operation and airflow throughout the residence.
Completed annual heating maintenance visit on HVAC system. Performed comprehensive inspection of blower assembly and electrical components, including blower wheel and capacitor. Verified all electrical connections at capacitor terminals are secure with proper wire routing. Inspected blower wheel for balance and operational wear, confirmed satisfactory condition with normal surface patina. All components photographed and documented for service records. System operational and ready for heating season.
Completed annual heating maintenance visit on HVAC system with Lennox thermostat. Performed comprehensive inspection of heating components, verified thermostat operation and temperature calibration, and confirmed system functionality. Filter size 20x25x4 noted as not included in service; customer responsible for filter replacement.
Responded to no cooling call with reported squealing noise prior to system failure. Upon arrival, found system completely inoperative with thermostat displaying 93°F and filter change reminder. Diagnosed failed blower motor in furnace unit after inspecting indoor air handler and ductwork system. Replaced defective blower motor assembly and restored system to normal operation. Verified proper airflow through supply ducts and confirmed all electrical connections secure. System tested and cycling correctly with adequate cooling output.
Responded to customer inquiry regarding HVAC system operation and thermostat functionality. Upon inspection, documented thermostat displaying 78°F with cooling system active and noted severely corroded electrical connections within junction box that pose potential safety and reliability concerns. Advised customer of findings and recommended scheduling repair service to address corroded wiring connections to prevent system failure.
Responded to customer inquiry regarding HVAC system operation and condition. Performed visual inspection of air handler unit and internal components, documenting equipment status with photographs. Inspected evaporator coil, refrigerant lines, electrical connections, condensate drainage system, and ductwork connections. Noted normal dust accumulation on coil surfaces consistent with regular operation. Verified proper installation of all refrigerant piping, electrical wiring, and safety controls. Addressed customer questions regarding system performance and maintenance requirements. Provided technical explanation of equipment operation and recommended routine filter maintenance schedule.
Completed basic monthly cooling maintenance visit on residential HVAC system. Inspected vertical cabinet-style air handler unit and confirmed proper operation of cooling system with thermostat actively calling for cooling (set point 76°F, indoor temperature 78°F). Verified system controls, condensate drain lines with shutoff valves, and overall equipment function per manufacturer specifications.
Responded to service call for air conditioning system with outdoor unit not operating while indoor fan was running. Upon arrival, verified thermostat was calling for cooling and indoor blower was functioning properly. Diagnosed issue with outdoor condensing unit and restored system to normal operation. Advised customer on importance of enrolling in maintenance program to maintain active service and labor warranty coverage.
Completed annual cooling maintenance visit on CCHP system. Installed new 20x20x4 air filter, verified electrical readings at 220-222V within normal operating parameters using digital multimeter, and inspected evaporator coil which showed proper condensation and clean fin condition with no blockages or significant debris accumulation.
Replaced faulty circuit breaker for heat kit in air handler unit and cleared condensate drain line. Removed access panel to electrical compartment, disconnected defective breaker, installed new breaker, verified proper wire connections and electrical continuity. Cleared blockage from condensate drain pan and drain line to restore proper drainage and prevent water overflow.
Responded to service call for outdoor condensing unit humming but not starting, with water discharge present. Diagnosed failed compressor (code 42) attempting to run but unable to start properly. Documented equipment condition and location of unit positioned on concrete pad against exterior wall with proper electrical connections present.
Completed annual cooling maintenance visit on Lennox HVAC system. Performed comprehensive inspection of outdoor condensing unit and indoor air handler, checked all electrical connections and control board operations, verified blower motor function, and replaced 20x20x4 air filter per service agreement specifications.
Responded to main line leak located behind stage area. Accessed under-floor crawl space and identified leaking drainage line near wooden floor joists. Repaired compromised PVC piping connection, secured installation with proper hangers and supports, and verified system integrity. All plumbing now functioning properly with no active leaks detected.