Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in November 2026. The most recent job was on November 5, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Diagnosed a Haier ductless mini split with a remote that would not switch to heat mode. Verified heating operation by measuring a discharge air temperature of 122.5°F at the indoor unit louver, confirming the system is capable of heating. Reset and reprogrammed the remote control to heat mode, restoring proper remote operation and mode selection.
Performed seasonal heating maintenance and inspected the evaporator coil assembly, where a heavily soiled, deteriorated strip of material with visible mold and grime was found and removed. Inspection camera review of the ductwork revealed rust and corrosion staining on the interior surfaces, along with dust and residue buildup; recommend monitoring the corrosion and scheduling duct cleaning if airflow or air quality issues develop. Filter replacement was not included in this visit.
Performed seasonal heating maintenance, including a combustion analysis (O2 6.2%, CO 70 ppm, CO2 8.4%) to verify safe, efficient furnace operation, and inspected the blower assembly, noting light dust accumulation on the wheel blades. Observed torn insulation on the adjacent line set and recommend repair to prevent heat loss and condensation. Air filter (20x25x4) was not included with this visit.
Performed recurring heating maintenance on two systems, including a combustion analysis on one furnace using a calibrated analyzer (O2 12.4%, CO 18 ppm, CO2 4.9%, flue/stack temperature recorded), confirming CO levels were within acceptable limits and combustion was operating safely. The 16x20x4 pleated air filters were not included in this visit, and replacement filters were left on site for installation.
Performed monthly plumbing inspection of the water softener system, confirming the control head was operating in normal softening mode and the brine tank was stocked with adequate salt. Inspected the copper supply piping, soldered joints, brass ball valve, and PEX transition fittings, finding no leaks, corrosion damage, or other visible deficiencies. All equipment and piping were in satisfactory working condition.
Performed annual heat pump tune-up on an 11-year-old system, including electrical testing of the air handler with a true RMS clamp meter to verify amperage draw on the blower and control circuits. Inspected the electrical compartment and noted dust and grime buildup on the breakers and wiring. System operation was checked and found to be within normal parameters.
Performed heating system maintenance under the CCH Basic plan, inspecting the air handler with its front access panel removed to evaluate the blower assembly, control board, relay/contactor, and 24V low-voltage wiring. Noted dust and debris accumulation within the cabinet and ductwork, along with disorganized wiring that should be monitored and tidied as needed. Air filter size could not be determined on site and remains undocumented; recommend verifying and recording the filter dimensions at the next visit.
Performed scheduled heating maintenance on the Carrier gas furnace, including installation of a new 16x25x1 return air filter and inspection of the galvanized flue piping, PVC condensate/vent lines, and surrounding ductwork for leaks, corrosion, or damage, with none observed. Verified combustion performance using a calibrated flue gas analyzer on natural gas, recording CO at 59 ppm, and confirmed the unit was operating safely and within acceptable parameters at completion.
Performed monthly heating maintenance on the Carrier WeatherMaker 8000 gas furnace, including a combustion analysis with a flue gas probe and digital analyzer to verify safe, efficient operation. Inspected the furnace cabinet, flue venting, condensate piping, and plenum connections, with no visible rust, leaks, or damage noted. Serviced the electronic air cleaner (EAC) filter and confirmed the system is operating normally.
Performed a pre-paid heating maintenance tune-up on two 11-year-old Carrier systems, including inspection of the air handler cabinet and evaporator coil, which showed light dust with no frost or ice buildup and only minor discoloration around a bracket bolt. Verified thermostat operation and settings, confirming the Carrier controller is functioning properly in heat mode with setpoints of 68°F heat and 72°F cool, with no physical damage observed.
Performed a scheduled monthly heating maintenance visit, inspecting the system and verifying supply air temperature at the ductwork with a digital pocket thermometer (71.9°F recorded). Inspected the coil assembly and noted dust and debris accumulation on the coil fins, which may reduce airflow and heat transfer efficiency. Filter was not included in this visit.
Performed scheduled quarterly heating tune-up on an 11-year-old furnace, including inspection and operational check of the heating system. Verified thermostat communication and call-for-heat response, confirming the Nest thermostat initiated a heating cycle and the system operated normally, with no visible frost, rust, cracks, or damage observed at the controls.
Performed seasonal heating tune-up on a 12-year-old single-stage gas furnace, including inspection of the blower motor, wiring, and internal components with the front panel removed. Verified PVC vent and condensate piping were intact and unobstructed, and confirmed normal operation with no signs of corrosion, leaks, or damage. System was left clean and operating properly, with no repairs required.
Performed a scheduled heating maintenance visit on the gas furnace, including inspection of the supply ductwork and condensate/PVC venting, with no signs of rust, frost, cracks, or leaks observed. Conducted combustion analysis on natural gas using a Bacharach analyzer to verify safe, efficient operation, and documented the service record on the unit. Replaced the 16x25x1 air filter per the recurring maintenance plan.
Responded to a leaking toilet reported after a customer installation, with increased leakage when the washer discharged. Inspected the toilet, base, and tank assembly and the supply line and fill valve, then protected the surrounding flooring and prepared the drain line for snaking. Corrected the leak source and verified the toilet operated properly with no leaks.
Performed scheduled heating maintenance on a ductless mini split system, opening the indoor unit to inspect and service the 20x25x1 air filters, which showed moderate dust and debris accumulation, and verifying the casing, vents, and internal components were free of frost, ice, or corrosion. Confirmed thermostat operation and room temperature readings (72°F), and noted the thermostat was found in the Heat/Off position with a 78°F setpoint, so the system was not actively calling for heat at the time of inspection.
Performed monthly basic maintenance on the central heating system, replacing the 20x20x1 air filter and inspecting the control cabinet, where heavy dust and debris accumulation was noted on the cabinet floor and around the wiring, pressure switch, and blower components. Inspected the return air grille, which showed dust buildup on the louvers and worn paint on the frame, and recommended periodic cleaning to maintain proper airflow and system efficiency.
Performed monthly heating maintenance visit, including inspection of the electric storage water heaters, access panels, drain valves, supply piping, and fittings for signs of leaks, corrosion, or damage, with none observed. Verified the units were in proper operating condition and the surrounding areas were clear, with no further issues identified at this time.
Performed warranty service on a Lennox gas furnace, accessing the control compartment and inspecting the integrated furnace control board, heat sink, wiring harnesses, and connections for proper operation. Verified furnace startup and operation, confirming the unit is functioning normally with no visible damage, corrosion, or ice buildup, and the system is cleared for continued service.
Performed scheduled heating system maintenance, including inspection of the furnace control compartment, capacitor, transformer, control board, and associated wiring connections, and replaced the air filter with a new 20x25x1 filter. Verified thermostat operation and display, with no abnormal conditions observed. Noted minor surface corrosion near the low-voltage wiring in the lower cabinet area for continued monitoring.