Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in November 2026. The most recent job was on November 4, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Performed scheduled heating system maintenance and installed a new 20x25x4 MERV-rated pleated media filter in the furnace/air handler cabinet, confirming correct airflow direction per the arrow marking. Verified heating operation by measuring supply air temperature at the register, which read 116.4°F, indicating the system is producing adequate heat output.
Responded to a musty, cellar-type odor reported in the rear rooms that began shortly after maintenance. Inspection of the air handler cabinet found a deteriorated, torn interior insulation lining near the top of the unit, and the supply ductwork showed dust and debris buildup along the seams and corners, both likely contributors to the odor. Documented findings and recommended repair or replacement of the damaged cabinet lining and cleaning of the affected ductwork to restore air quality.
Diagnosed Honeywell Home smart thermostat that was not connecting to Wi-Fi or the mobile app. Verified unit was powered and operating normally in heat mode with a warning indicator and weak connectivity status displayed. Restored the thermostat's network connection and confirmed communication with the mobile app, with the unit now calling for heat and functioning properly.
Performed preventive maintenance tune-up on a 2-year-old Lennox SLP99UH070XV36B gas furnace and Lennox EL18XPV-036-230 heat pump, inspecting and testing both heating and cooling operation. Accessed the evaporator coil and found the fins clean and in good condition, with light mineral residue and oxidation on the coil return bends and minor tarnish on the copper line fitting, none of which affects performance at this time. Both systems operated properly and are covered under the remaining Lennox warranty; recommend monitoring the coil return bends and fitting during future maintenance visits.
Responded to a no-cooling complaint on the A/C system and diagnosed a low refrigerant condition, confirmed by the thermostat displaying a system error 41 warning. Inspected the system to verify the diagnosis and documented the fault code for further refrigerant system evaluation and repair.
Inspected the heat pump system in response to intermittent switching between compressor heat and auxiliary heat, and checked refrigerant levels and system operation ahead of the heating season. Inspection of the air handler found corrosion and residue on the blower motor wiring connector terminals, and the reversing valve solenoid coil and associated connections were examined with no frost, ice, or rust present. Corroded connector condition noted as a potential contributor to the intermittent operation.
Performed a routine plumbing inspection under the monthly maintenance membership, including a visual assessment of the wall-mounted tankless water heater, its venting, control panel, and associated supply, shutoff valve, and drain connections. Inspected exposed overhead supply and PVC drain/waste piping, fittings, and shutoff valves, finding no visible corrosion, leaks, frost, or damage, and all components appeared in serviceable condition.
Replaced the discharge line running from the geothermal system to the dry well, installing new PVC piping through the crawl space, supported with straps and ties to the floor joists. Excavated a trench across the yard and laid continuous PVC pipe at depth to the dry well, completing the connections and fittings to restore proper drainage from the geothermal unit.
Responded to a no-operation call and found repeated E7 igniter fault codes in the thermostat error history. Inspected the furnace cabinet and found corrosion and rust staining on the cabinet wall and floor, along with debris buildup and field-spliced wiring connections, and documented these findings with photos for further repair.
Accessed the washing machine supply valves through an opening in the wall and replaced the washer faucet, then verified the connections for leaks. Inspected the braided stainless steel supply hoses, shutoff valve, and drain hose within the wall cavity, and confirmed all fittings were secure with no active leaks.
Responded to a reported slow/non-draining double-basin kitchen sink and inspected both drains, finding heavy debris, grease, and mineral buildup around the strainers and drain openings. Cleared the obstruction from the drain line, cleaned and reseated the basket strainers, and flushed the system with water to verify unrestricted flow. Confirmed both basins now drain properly with no standing water or leaks at the drain connections.
Diagnosed an A.O. Smith Signature 900 hybrid heat pump water heater reporting loss of hot water and abnormal compressor/fan noise in heat pump mode. Opened the electrical access panel and performed multimeter continuity and voltage testing on the electric heating element circuits and thermostat/control wiring, and flushed the tank to remove sediment. The unit was left operating in Electric mode with hot water service restored.
Performed seasonal heating maintenance on a Carrier gas furnace, inspecting the cabinet, PVC condensate and venting lines, gas supply connection, electrical junction, and wiring for leaks, corrosion, or damage. No frost, rust, or major deficiencies were found. Noted worn, crinkled flexible foil-wrapped ductwork at the return side for future attention, and verified the condensate drain was properly routed. Applied the maintenance service card to the unit cabinet; a 20x25x4 filter was not included with this visit.
Performed scheduled preventive maintenance on the heating and cooling systems, including inspection of the thermostat controls and operating settings. Found the 4-inch Filtrete return air filter heavily loaded with dust and debris and contaminated with fiberglass insulation fibers lodged in the pleats, which restricts airflow and reduces system efficiency; the thermostat's "check filter" alert was active. Recommend replacing the filter and checking the return air path for a source of insulation shedding.
Performed annual heating maintenance visit, including replacement of the 20x25x4 return air filter and verification of system airflow. Measured supply duct temperature at 74°F with a digital probe thermometer to confirm proper heat output, and inspected the heat pump water heater, which was operating normally at a 120°F setpoint with no signs of frost, rust, or damage.
Performed scheduled heating system maintenance on gas furnace. Inspected furnace and verified normal operation, including a visible burner flame at the sight glass and no active diagnostic codes. Confirmed air filter slot is accessible and a MERV 8 filter is installed with proper airflow orientation; filter size 16x25x4 was not supplied as part of this visit. Checked condensate PVC drain piping and secured connections, and verified thermostat operation with room temperature reading 76°F and no visible damage or irregularities. System is operating normally at completion.
Performed annual heating system maintenance, including inspection of the air handler cabinet and evaporator coil, which showed a light dust accumulation on the fins with no frost, ice, or corrosion present. Inspected the outdoor unit control panel and verified the control boards, wiring harnesses, and connections were intact with no signs of burning, rust, or damaged components. Installed a new 20x25x4 filter and confirmed the system was operating properly at completion.
Appointment was cancelled due to technician unavailability, so no maintenance was performed on the water-source heat pump. Thermostat was observed in heat mode following schedule with a 67°F setpoint and indoor reading of 67°F at 56% humidity, and the equipment showed no visible damage, rust, or ice. Maintenance remains outstanding and should be rescheduled.
Performed seasonal heating tune-up on a Carrier gas furnace, inspecting the burner compartment, manifold, gas valve, threaded gas connections, and wiring, with no leaks, corrosion, or abnormal conditions observed. Verified the system with the Honeywell ProSeries thermostat and confirmed the unit is operating normally with no issues reported.
Performed seasonal heating tune-up on Lennox EL296UH070XE36B-05 gas furnace, including a combustion analysis to verify safe, efficient burner operation and flue gas readings, and confirmed proper heat call and thermostat operation in heat-only mode with a 79° setpoint. System was found operating properly with no repairs required.