Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in October 2026. The most recent job was on October 29, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Responded to a no-heat call on a gas furnace that would not start. Inspected the furnace, gas supply, venting, ductwork, and return air filter, and verified thermostat operation. Performed diagnostic checks of the ignition sequence, and replaced the dirty return air filter to restore proper airflow.
Responded to a recurring thermostat warning and reviewed the error history, which showed repeated E2 faults for the gas furnace low stage pressure switch opening during heating calls. Inspected the furnace pressure switch assembly, including the switches, wiring connections, and pressure hose, and found no visible damage, corrosion, or loose terminals. Further testing of the low stage pressure switch circuit and draft inducer operation is recommended to isolate the intermittent fault.
Performed an on-site estimate for installation of a customer-supplied tanked electric water heater replacing the existing unit. Inspected the existing water heater, CPVC supply piping, and adjacent electrical panel and well pump/pressure tank area, and determined that short sections of piping will need to be relocated to accommodate the taller replacement tank. Provided an installation quote for the replacement, including the necessary pipe modifications.
Performed scheduled monthly heating maintenance, verifying thermostat operation in Heat mode with fan set to Auto and the system responding to a call for heat. Conducted a combustion analysis on the furnace, recording O2 at 9.4%, CO at 6 ppm, and CO2 at 6.6%, with CO within safe operating limits. Flue temperature probes did not register readings during the test, so stack temperature and efficiency could not be documented. Updated the filter service tag with the visit record.
Performed seasonal heating maintenance on the gas furnace, including a combustion analysis with a Bacharach analyzer that returned O2 at 11.3% and CO at 21 ppm on natural gas. Updated the maintenance history log affixed to the unit panel. The customer's filter, a 20x25x4, was not included in this visit.
Performed seasonal heating maintenance inspection and verified thermostat operation, confirming proper display and mode/fan functionality with the system calling for and maintaining setpoint (readings of 72–74°F observed). Filter size could not be determined during the visit, so filter replacement was not completed and size verification is recommended on the next service.
Performed annual heating maintenance and inspection on the gas furnace, including a combustion analysis that returned normal results (O2 11.8%, CO 9 ppm, CO2 5.2%) and confirmed safe, efficient burner operation. Verified thermostat operation and system controls; the system was left operating properly with no deficiencies noted.
Performed a seasonal gas furnace maintenance inspection, accessing the burner compartment, blower assembly, and control components, and replaced the air filter with a new 16x25x1 filter supplied by the technician. Observed surface rust and corrosion on the burners and manifold along with heavy dust accumulation on the cabinet, and noted these conditions for the homeowner's awareness and future monitoring.
Performed routine tune-up and heating maintenance on the gas-fired boiler, inspecting the burners, wiring, gas piping, flue venting, and hydronic piping, valves, and controls for proper operation. Verified the system responded correctly to a call for heat at the Honeywell thermostat, with the unit running in heat mode. Noted that the thermostat backplate does not fully cover the damaged wall surface behind it and recommend wall repair or a cover plate for a cleaner installation.
Performed annual pre-season tune-up on a Goodman GCES96080AMNAA 96% AFUE gas furnace (approximately 5 years in service), inspecting the heat exchanger, burner assembly, flame sensor, ignition system, condensate drain, and flue/vent piping prior to first operation of the heating season. Inspected the 20x20x4 MERV 13 media filter and verified proper airflow through the return and supply plenum; unit was left operating normally with no visible rust, frost, or damage observed.
Performed scheduled monthly heating system maintenance, including replacement of the 16x25x1 air filter. Inspected the thermostat controls and verified proper operation in heat mode with the display reading correctly against the 72° setpoint. Replaced the thermostat's AA batteries and confirmed the unit was clean, intact, and functioning normally.
Performed monthly heating system maintenance on the gas furnace, including replacement/servicing of the electronic air cleaner filter. Conducted combustion analysis on the natural gas appliance using a Bacharach combustion analyzer to verify safe and efficient burner operation, with CO readings monitored at approximately 20 ppm. System was inspected and left operating properly.
Performed annual heating maintenance on a Nordyne gas furnace, including inspection of the blower assembly, inducer motor, flue venting, control board, wiring connections, and gas valve, with electrical readings verified using a digital multimeter. Identified the system's 18x30x1 pleated air filter and confirmed its size for future replacement, and found no evidence of rust, frost, or component damage, with the unit operating normally.
Performed a heating tune-up on a 9-year-old Trane furnace, including inspection of the cabinet, ductwork plenum, controls, and electrical connections, with no signs of frost, heavy rust, or significant damage noted. Accessed the blower assembly and found dust and debris buildup on the squirrel-cage fan wheel and housing; cleaned the blower components to restore proper airflow and system efficiency.
Performed a return-air and supply register inspection, confirming the floor vent register is properly seated, free of damage, rust, or frost, and the duct opening is unobstructed. A follow-up visit is required to deliver a box of 8x16x1 filters for the system's filtration needs.
Performed a seasonal heating maintenance on the gas furnace, including a combustion analysis in run mode that measured 7.3% O2 and 21 ppm CO in the flue gases. Verified flame sensor microamp output at 3.9 µA DC using a true RMS clamp meter, confirming proper flame rectification. Filter replacement was not included in this visit.
Performed a heating tune-up on a Lennox gas furnace, inspecting the gas piping, condensate drain, venting, and wiring connections. Verified combustion performance with a combustion analyzer, recording O2 at 13.0%, CO at 22 ppm, and CO2 at 5.3%, and confirmed the unit was operating safely. Noted loose wiring with exposed wire connectors in the upper cabinet and duct tape securing the PVC vent line, both of which may warrant follow-up.
Performed a routine monthly heating maintenance visit on the Carrier gas furnace, including replacement of the 16x25x2 air filter and inspection of the furnace cabinet, ductwork, and condensate drain components. Verified smart thermostat operation, with the unit displaying a 72°F room temperature and 46% humidity and responding properly to heating and cooling setpoints. The system was left operating normally.
Performed scheduled heating maintenance on a WaterFurnace Premier 2 geothermal heat pump, inspecting the cabinet, ductwork, and water-side piping and valves with no signs of frost, rust, or damage. Verified loop pressure on the Geo-Flo gauge at approximately 10–20 PSI and noted condensation on the insulated loop piping along with a small tear in the insulation that should be repaired. Customer-supplied filters were not included in this visit.
Performed a seasonal furnace tune-up and verified proper heating operation. Confirmed thermostat functionality in heat mode with the fan set to auto, and measured a supply air temperature of 128.3°F at the floor register, indicating the furnace is producing adequate heat output. Noted dust and debris accumulation on the supply register slats.