Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in October 2026. The most recent job was on October 28, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Inspected the electric water heater at the customer's request and confirmed it was leaking and in need of replacement, as the customer had anticipated. Documented the unit's condition and installation details with photos, and discussed replacement with the customer, who approved proceeding with a new water heater.
Diagnosed a water stain on the kitchen ceiling as originating from the upstairs toilet and removed the toilet to inspect the seal. Found the closet flange heavily corroded and the surrounding flooring stained and deteriorated from a failed wax ring seal, with the flooring cut away around the flange and the subfloor exposed. The toilet remains disconnected pending flange repair or replacement and subfloor assessment.
Performed monthly basic maintenance on the gas-fired condensing furnace, inspecting the burner assembly, gas valve, control board, wiring, gas supply piping, flue/vent connections, and condensate pump, with no frost, ice, or major rust observed and light dust and grime noted on the unit. Filter size was not determinable and remains unknown, so it is flagged for documentation on the next visit. Also performed a visual check of the adjacent gas water heater, including the draft hood, flue vent, gas control valve, and supply connections, and took a combustion/atmosphere reading with a handheld meter.
Performed an on-site evaluation of the cooling system after a reported compressor short that was tripping the breaker. The existing R-22 split system, installed in 1999, was inspected at the exterior condenser and disconnect and at the indoor Ruud gas furnace and plenum. Because the compressor has failed on an obsolete R-22 unit, a replacement estimate was prepared for the homeowner, who is preparing to sell the home.
Performed a seasonal tune-up on the Daikin split system, including a cleaning and operational check of the heating and cooling components. Verified thermostat operation, with the unit displaying normal setpoints and humidity readings. Updated the maintenance history log on the air handler; a 20x20x4 filter was not supplied with this visit.
Responded to a loud rumbling noise from the furnace blower assembly that caused the system to be shut off while operating in cooling mode. Inspection of the blower wheel revealed heavy dust and grime buildup with debris lodged between the blades, creating an imbalance and causing the noise. The blower wheel was cleaned and the debris removed to restore smooth, quiet operation.
Completed new construction HVAC finish, including installation of two gas furnace/air handler units with supply plenums, galvanized trunk ductwork, and transitions, supported with strut and hanger rods. Connected condensate PVC drain piping, gas and refrigerant line fittings with isolation valve, and verified all connections, unit labeling, and system components were secure and free of visible damage.
Installed a Lennox mini split system, mounting the outdoor condenser on a bracket with a weatherproof disconnect and routing the refrigerant line set through a PVC cover to the exterior wall, with condensate drain piping installed at the base of the unit. Connected the R-32 system to a digital refrigerant manifold and vacuum gauge for commissioning, with readings indicating approximately 307 psig high side pressure, 23.4°F subcooling, and 71.8°F suction line temperature, and verified the equipment is installed cleanly and secured with no visible damage.
Performed a seasonal tune-up and system inspection on the furnace/air handler, replacing the 16x25x1 return air filter with a new Filtrete filter to restore proper airflow. Verified thermostat operation with the system in heat mode, confirming the display, setpoint, and fan settings were functioning correctly.
Replaced two locking-enclosure thermostats, including a Honeywell Home digital unit and a Rheem dial-style unit, with updated thermostats. Inspected and cleaned the thermostat guard enclosures, noting dust accumulation inside and peeling paint and caulk residue along the mounting edges.
Performed scheduled monthly maintenance on the heating system, including inspection of the Bryant air handler, refrigerant line set, condensate drain line, and Honeywell digital thermostat operation. Replaced the air filter with a new 20x20x1 filter to maintain proper airflow and system efficiency. All components were found in good working condition with no visible damage, leaks, or corrosion noted.
Responded to an urgent no-heat call and inspected the wall-mounted Honeywell Home ProSeries thermostat, which was powered and communicating, displaying a heat call with a 68°F setpoint against an 83°F room temperature reading. Confirmed the thermostat was set to Heat mode with fan on Auto and was operating normally, with no display or control faults observed, indicating the reported issue did not originate at the thermostat.
Inspected the crawl space and reattached the disconnected dryer vent to restore proper exhaust to the exterior. Inspection revealed a heavily corroded, rust-damaged metal duct section with torn foil wrap and heavy dust and cobweb accumulation on surrounding ductwork and piping, indicating moisture exposure that should be addressed. Evaluated the system for a whole-house humidifier installation and recommended repair of the corroded ductwork.
Completed annual heating maintenance on one system, including inspection of the electrical control compartment and run capacitor, with wiring connections, mounting strap, and control board found intact and the compartment cleared of dust and spider webs. Verified heating operation by measuring a supply air temperature of 103.1°F at the ceiling diffuser, and confirmed the vent was clean and free of damage. The system is operating properly.
Performed monthly heating maintenance on the system, including electrical current verification with a true RMS clamp meter to confirm proper amperage draw during operation. Inspected the electronic air cleaner cabinet, which showed a dusty pleated filter media and light debris buildup along the access door. Verified the unit is operating within normal parameters; a replacement 20x25x4 filter was not part of this visit.
Performed annual heating maintenance on two systems, inspecting the outdoor unit and clearing cobwebs, dust, and debris from the louvered condenser panel to restore proper airflow across the coil. Replaced the 16x20x4 air filter and verified heating operation through the thermostat, confirming the system called for heat and maintained the 70°F setpoint with stable indoor conditions.
Completed monthly heating maintenance on two systems, including inspection of the filter rack and installation of a Filtrete 4-inch media filter in the return-air filter slot to maintain proper airflow. Verified that the adjacent dual tankless water heaters showed normal operation at approximately 120°F, with intact venting, gas line, and plumbing connections and no visible leaks, corrosion, or damage.
Returned to site and replaced the furnace burner assembly. The removed burners showed heavy rust and corrosion on the rear-row ports, with soot-like discoloration and residue on the front row, indicating deterioration that warranted replacement. Installed the new burner assembly and verified proper fit and operation.
Performed seasonal heating maintenance on two cold climate heat pump (CCHP) systems, verifying thermostat operation and calibration at both wall-mounted controls, which displayed stable 73° room temperatures with heat mode functioning properly. Confirmed thermostats are intact, securely mounted, and set within the authorized community temperature ranges, with no signs of damage or corrosion. The 20x25x4 filters were not included in this visit.
Performed annual heating system maintenance, including a combustion analysis with a digital combustion analyzer to verify efficient and safe burner operation, and inspected the air handler cabinet and evaporator coil, which were found clean with no frost, ice, or corrosion. Installed a new 20x25x4 filter to maintain proper airflow, and the system was left operating normally.