Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in October 2026. The most recent job was on October 23, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Performed an on-site evaluation of the cooling system after a suspected failed thermostatic expansion valve (TXV) on the existing Heil system, which is of undetermined age. Inspected the Carrier gas furnace and air handler closet, including the 16x20 filter slot, refrigerant lines, condensate piping, and ductwork, and checked the thermostat for proper operation. Findings were documented with photos to support a replacement estimate for the faulty TXV and associated cooling system components.
Cut an access opening in the ceiling drywall to expose the leaking copper water supply line and repaired the leak at the affected joint, restoring proper water line integrity. Access was limited to the cut opening only; drywall repair was not included in the scope of work.
Performed warranty diagnosis and repair of the supply air distribution system. Inspected the galvanized sheet metal plenum/boot seated on its framed lumber platform and verified connection integrity at the duct flange, noting a bent corner and seam creasing. Corrected and secured the duct connection, confirmed proper alignment with the floor register opening, and prepared the system for final register installation.
Replaced the failed electronic expansion valve (EEV) at the indoor A-coil under manufacturer warranty, restoring proper refrigerant metering to the evaporator. Reworked and secured the refrigerant line insulation and sensor wiring at the coil, and verified the system was operating correctly after the repair.
Performed seasonal heating maintenance on a gas furnace, including inspection of the control board and wiring and a combustion analysis with a Bacharach analyzer, which recorded 10.2% O2 and 19 ppm CO in the flue gases. Noted disorganized, loose wiring with exposed conductor ends near the control compartment, along with heavy dust and debris buildup in the cabinet, and recommend corrective wire management and cleaning. The 16x25x4 filter was not included in this visit.
Performed an on-site evaluation for replacement of an aging, deteriorated Kenmore upright gas furnace, inspecting the unit, PVC venting and condensate piping, and plenum/ductwork with foil-faced insulation. Also inspected the exterior gas meter and regulator assembly, noting corroded piping and eroded soil at the base of the riser. Documented equipment condition with photos and determined that full system replacement is recommended.
Performed seasonal heating maintenance under the customer care agreement, inspecting the air handler's A-frame evaporator coil and blower assembly. Observed light dust and residue accumulation on the coil fins and blower wheel blades, with the condensate drain, refrigerant lines, and insulation in serviceable condition. The 20x25x4 filter was not included with this visit.
Performed scheduled monthly maintenance on the high-efficiency gas furnace, including visual inspection of the cabinet, supply plenum and ductwork, and PVC condensate/vent piping, with no evidence of corrosion, frost, or damage. Verified flue/vent pipe temperature with a clip-on thermometer (79.1°F) as part of operational checks, and confirmed the system is operating normally with unobstructed combustion air and venting.
Performed a clean and check tune-up on the gas furnace, removing the lower access panel to inspect the blower assembly, wiring, relays, and control components. Verified combustion performance with a UEi C161 analyzer, recording 0 ppm CO, 7.8% O2, and 7.4% CO2, confirming safe and efficient operation. Visually inspected the plenum, ductwork seams, and venting connections, and found no issues requiring correction.
Performed a furnace tune-up, including combustion analysis with a calibrated analyzer to verify safe operation and check CO levels, and inspected the outdoor condenser unit and its electrical disconnect. Evaluated the non-functioning humidifier to diagnose the cause of the malfunction.
Performed a heating tune-up on a 13-year-old Lennox furnace, inspecting internal components, wiring connections, and the gas valve, and verifying flame sensor microamp readings with a clamp meter. System was found free of visible damage, rust, or wear, and thermostat operation was confirmed with the unit calling for heat and responding properly to setpoint.
Inspected the attic HVAC system for IAQ concerns and found the flexible supply ducts torn at the outer jacket, with fiberglass insulation exposed at the plenum connection and loose insulation debris scattered throughout. Documented the damage consistent with rodent activity, and the damaged duct sections will need repair or replacement as part of the planned attic insulation removal and reinsulation.
Performed a seasonal heating tune-up on an 11-year-old furnace, including inspection of the blower compartment and 14x25x1 pleated air filter, which was dusty and debris-laden and noted for replacement. Verified safe combustion performance with a calibrated combustion analyzer, recording CO at 3 ppm, O2 at 10.8%, and CO2 at 5.7%, all within acceptable operating ranges.
Performed annual heating maintenance inspection on the attic-mounted air handler/furnace, verifying proper unit operation, inspecting the refrigerant line set and filter drier, and checking the duct connections and surrounding insulation for any issues. Confirmed the 20x20 air filter size for the system and inspected the electric water heater in the lower-level utility space, noting visible moisture and staining on the floor around the base of the unit. System was left operational following the inspection.
Performed scheduled heating maintenance inspection, verifying the 20x20x4 air filter was properly seated with correct airflow orientation in the duct housing above the air handler, with no frost, ice, or rust observed. Inspected the outdoor Goodman condenser unit, noting light dust on the coil grilles and leaf litter, weeds, and mulch debris around the pad, and confirmed the disconnect, conduit, and insulated refrigerant line set were intact and secure.
Performed scheduled monthly heating maintenance on the Daikin heat pump system. Visually inspected the outdoor condenser and found the cabinet, grille, and surrounding area free of frost, ice, rust, or damage. Verified thermostat operation, noting a displayed room temperature of 65°F with heat and cool setpoints of 62°F and 66°F, and recommended finishing the patched drywall around the thermostat.
Responded to a leaking humidifier complaint and found heavy mineral scale and corrosion buildup on the humidifier components and surrounding cabinet interior, along with accumulated dust and debris. Performed the complimentary heating system maintenance, and the customer was re-enrolled in the maintenance membership program.
Performed seasonal heating maintenance on the attic-mounted Honeywell air handler, replacing the return air filter with a 16x20x4 media filter and inspecting the system for proper operation. Evaluated the evaporator coil, noting light dust accumulation on the fins and minor surface corrosion on the galvanized baffle edge, with no active leaks, frost, or damage observed in the surrounding condensate and piping.
Performed seasonal heating maintenance on the system, including inspection of the smart thermostat, which displayed clearly and operated normally, and a visual inspection of the blower motor wiring harness and multi-pin connector. All conductors were intact and neatly routed, with no fraying, burning, or corrosion observed. The 20x20x4 filter was not included in this visit.
Diagnosed a gas furnace short-cycling (approximately 1-minute run, 3-minute off cycle) that began after a new thermostat and AC installation. Inspected the furnace control board and low-voltage wiring, finding multiple twisted/spliced conductors at the terminal strips with no visible burn, rust, or frost damage, and used a dual-port digital manometer to test the pressure switch and venting circuit for proper draft and operation. Findings point to a control or pressure-related cause for the cycling, and the system was evaluated for continued safe operation.