Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in October 2026. The most recent job was on October 21, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Responded to a no-heat complaint on a gas furnace and inspected the unit with the burner/blower compartment open, checking the inducer assembly, control board, wiring harness, flue venting, and condensate/PVC drain connections. Verified thermostat operation in heat mode with fan set to auto, confirmed the call for heat, and restored furnace operation. Heat is now functioning and the system is cycling normally.
Performed annual heating maintenance inspection on the furnace/air handler, verifying cabinet and panel condition and checking return air temperature at approximately 77°F. Inspected the outdoor condenser's electrical compartment, confirming the contactor, run capacitor, control board wiring, and ground connection were secure and in good condition with no signs of corrosion, frost, or physical damage. Verified the 18x20x1 filter was included and the unit's maintenance history documentation was updated and accessible at the equipment.
Responded to a no-heat call on a 4-year-old Goodman heat pump and air handler and inspected the air handler control compartment, where I found corrosion and rust on the contactor/relay terminals, terminal block screws, and surrounding components. After diagnosing and addressing the condition, I verified system operation at the thermostat, confirming the unit is calling for heat with Stage 1+2 and the blower running on a 73°F setpoint. Recommended continued monitoring of the corroded electrical components, as they may require replacement if moisture exposure persists.
Performed monthly heating system maintenance visit, verifying thermostat operation in heat mode with a call for heat at a 74° setpoint against a 70° ambient reading. Inspected the gas-fired water heater and its flue collar, flexible gas connector, and temperature and pressure relief valve piping, finding no signs of rust, frost, or visible damage. Filter replacement was not included in this visit, and the system is operating normally.
Responded to a customer report of ceiling condensation and inspected the A/C condensate drain line for proper drainage and discharge outside the home. Documented water-stain discoloration on the ceiling in the affected area, consistent with moisture intrusion, and photographed the surrounding ceiling and wall surfaces for the service record. Findings are documented for follow-up repair of the condensate drain line and evaluation of the stained ceiling.
Performed an on-site estimate for a geothermal system replacement after the existing unit failed, evaluating the basement mechanical area, including the existing cabinet-style heat pump, insulated loop piping, water heater and expansion tank connections, gas and flue routing, and electrical panel and ductwork configuration. Since the homeowner has been satisfied with their current Water Furnace equipment, the replacement proposal centers on that brand, which is known for reliable, high-efficiency geothermal performance, and was documented with photos of existing conditions to support a like-for-like changeout.
Responded to an emergency call for a suspected failing bearing on a ten-year-old gas furnace and inspected the inducer motor assembly. Heavy rust and corrosion were found on the flue/vent pipe, inducer housing, and burner box, with additional corrosion at the gas valve fittings. The inducer motor, pressure switch and tubing, gas valve, and wiring connections were all checked, and the unit's condition and recommended repairs were noted for follow-up.
Inspected the reported ceiling water stain and traced it to the overhead joist cavity, where the PVC drain-waste-vent piping, elbow fittings, and adjacent copper supply lines and soldered joints were examined. All visible piping, couplings, and joints appeared dry with no active leakage, corrosion, or visible moisture damage at the time of inspection. Documented the findings with photos and recommended monitoring the stained area for any recurrence.
Performed scheduled monthly maintenance under the Basic plan, including filter service and heating system inspection. Verified thermostat operation in heat-only mode with fan set to AUTO, confirming the set point of 71° and stable indoor conditions at 74° with 35% humidity. Inspected the adjacent electric water heater and supply connections, finding no visible leaks, rust, or damage, and noted no operational concerns at the time of service.
Performed seasonal heating maintenance on the system, including inspection of the 20x25x4 media air filter housing, where staining and discoloration were noted. Verified heating performance by measuring supply air temperature at approximately 107°F with a digital pocket thermometer, confirming proper heat output. Filter replacement was not included in this visit.
Performed a seasonal heating tune-up on a gas furnace (Freedom 90 series) installed in the basement, verifying proper operation and normal heating cycle. Inspected the plenum, vent piping, flexible gas line, and ductwork connections for integrity, and confirmed the Honeywell Chronotherm III programmable thermostat was calling for heat and responding correctly at its 70° setpoint. The system was found in good working condition with no repairs required.
Responded to a callback for a system running constantly in emergency heat mode, failing to reach a 72°F setpoint (holding at 70°F). Inspected the Lennox vertical air handler, condensate drain assembly, and associated ductwork and plenum, and evaluated system operation to diagnose the heating performance issue. Documented the equipment condition and unit configuration for service history.
Responded to a malfunctioning tanked water heater under warranty and found water pooled on the floor around the adjacent pump, with a visible crack in a component indicating a leak and failure. Documented the damage with photographs to support the warranty claim and isolated the unit pending replacement or repair.
Performed seasonal heating maintenance on a Bryant gas furnace, including inspection of the unit, PVC venting, supply ductwork, and gas piping connections. Installed a new 20x25x1 air filter as part of the monthly maintenance plan, and confirmed the system was operating properly at completion.
Performed heating maintenance and diagnostic on a gas furnace reported to have an ignition issue. Removed the furnace access panel to inspect the burner assembly, gas valve, and control wiring, and ran the system through thermostat test mode (Stage 1) via the Honeywell ProSeries thermostat to verify the ignition sequence and heat operation.
Performed an initial plumbing maintenance inspection of the bathroom, examining the vanity sink drain assembly, including the tailpiece, P-trap slip-nut connections, and flexible supply lines with chrome shutoff valves, and found all components intact with no leaks, corrosion, or cracks. Inspected the toilet fixture and found the bowl clean with normal water level and no visible issues. No repairs were required, and all fixtures were left in proper working condition.
Performed scheduled monthly heating maintenance, including borescope inspection of the burner assembly and evaporator coil/fin section. Observed light surface wear and minor oxidation on the burner components, along with isolated rust spotting, seam corrosion, and dust and grime accumulation on the coil fins; no operational failures were found. Recommend monitoring the corrosion at future visits and cleaning the coil if buildup increases.
Performed seasonal heating maintenance on the gas furnace, including inspection of the cabinet, ductwork connections, plenum, and associated electrical and condensate/plumbing connections. Replaced the 20x25x4 air filter, and noted worn, torn foil tape and insulation on the supply-side ductwork that may require resealing to maintain system efficiency. System was left operational following the visit.
Performed seasonal heating system maintenance under the CCH Basic plan, including inspection of the air handler cabinet, coil, blower assembly, and drain pan. Observed surface rust and corrosion along the coil frame, oxidation on copper return bends, and mineral residue and debris in the cabinet and drain pan; recommend monitoring and cleaning as needed to prevent further deterioration. No air filter was supplied with this visit (20x20x4 size required).
Diagnosed a furnace lockout and replaced the failed control board, high limit switch, and air pressure switch. Verified supply air temperature rise with a digital thermometer (115.1°F reading at the cabinet) to confirm proper heating operation and safety circuit function after installation.