Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in October 2026. The most recent job was on October 19, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Evaluated the installed air handler/furnace, which showed condensation and mineral residue on the cabinet exterior, with a PVC condensate drain line and portable dehumidifier in place. Verified refrigerant charge using a digital charging scale. Provided time-and-material rates for removal and reinstallation of the unit; if the work proceeds, the supply plenum will also require insulation to prevent further sweating.
Performed routine monthly heating maintenance on the central system, including inspection of the blower assembly, which was found clean and intact with no rust, cracks, or debris buildup. Verified heating operation by measuring supply air temperature at the floor register, which read approximately 127.7°F. The 16x25x4 filter was not included in this service.
Responded to emergency no-heat call on a 6-year-old Daikin gas furnace and reviewed the thermostat error history, which showed recurring fault codes E9 (general error), E2 (low-stage pressure switch open during heating), and B0 (blower motor not running), along with an active fan failure alert. These codes point to an inducer/pressure switch circuit and blower motor fault preventing the furnace from completing its heating sequence. The system was diagnosed and the fault condition documented for repair of the affected components to restore heat.
Responded to an emergency no-heat call on a newly installed Lennox EL280DF090 gas furnace that was cycling briefly with no airflow from the supply vents. Inspected the thermostat, which showed a 73° setpoint against a 67° indoor reading, and examined the gas valve assembly and associated low-voltage wiring, finding the solenoid, wire harness connections, and flexible conduit intact with no visible damage, rust, or frost. Note: the provided details do not specify the root cause identified or the corrective action performed, so those items should be confirmed by the technician before finalizing this record.
Responded to a heat pump malfunction, reviewing the Carrier thermostat's system event log, which showed a high pressure switch open fault (code 31) followed by a 4-hour high pressure lockout (code 84). Diagnosed the high-pressure condition and performed warranty repairs to restore proper refrigerant circuit operation and clear the lockout. Verified system performance and confirmed the unit is cycling normally with no active faults.
Performed a monthly heating maintenance visit, including electrical diagnostics on the furnace blower motor and control circuit using a digital multimeter to verify proper voltage and component operation. Removed the existing air filter and installed a new 20x25x4 Filtrete electrostatic filter, securing the access door to restore proper airflow and system operation.
Installed a Solaris air ionizer inside the supply plenum and mounted the Solaris IAQ System Control Center on the air handler side panel, with power and control wiring routed and secured. System status indicators were confirmed active. Follow-up visit required to install the home improvement combo indoor air quality components to complete the system.
Responded to an emergency no-heat call on a York gas furnace and inspected the system, including the Honeywell thermostat (calling for heat with the fan set to "On") and the furnace cabinet, venting, and surrounding connections, with no visible damage, frost, or rust noted. Evaluated whether the failure was related to the recent service visit and verified the system's operating status after the on-site check.
Performed an on-site evaluation of a non-operational, 23-year-old Goodman heating system with no heat, and inspected the outdoor condenser, which showed surface rust, faded paint, and weathering, along with its electrical disconnect and line set. Reviewed heat pump replacement options and system sizing considerations with the customer in preparation for a replacement quote.
Performed a semi-annual heating tune-up on a Bryant gas furnace installed in a utility closet, inspecting the cabinet, plenum, PVC condensate/vent piping, and galvanized flue connections for corrosion, leaks, or damage. The unit was found operating properly with no frost, rust, cracks, or other deficiencies noted, and the adjacent water heater and associated piping were also visually checked with no conspicuous issues observed.
Performed a scheduled monthly heating inspection, visually checking the furnace cabinet, gas line, pressure switches, wiring harnesses, inducer/blower assembly, and hose connections, with no damage, corrosion, or abnormal conditions observed. Replaced the 20x20x1 pleated return air filter and marked the installation date and airflow direction on the filter housing for future reference.
Performed annual spring maintenance on the heating system, including inspection of the control board, wiring, and sensor assembly, and verified electrical operation with a clamp meter (47 reading recorded). Noted heavy rust and corrosion on the cabinet floor and loosely bundled wiring with wire nut connections, and recommend monitoring or further evaluation. The 20x25x4 filter was not included in this visit.
Responded to a ductless mini split indoor unit leaking condensate into the living space, causing drywall and flooring damage. Inspected the wall-mounted air handler, cleared the condensate drain path, and verified proper drainage and unit operation, with no further leakage observed.
Performed scheduled heating-mode maintenance on the heat pump system, inspecting the air handler cabinet, evaporator coil, and refrigerant line insulation. The coil fins were found largely clean with light dust, while the suction line insulation showed dust and wear and a patch of mineral residue or corrosion was noted on the cabinet panel. Verified system performance by measuring supply air temperature at the wall-mounted vent, which showed dust buildup on the louvers.
Performed scheduled monthly heating maintenance on the vertical gas furnace, including removal of the lower access panel to inspect the blower assembly, squirrel-cage wheel, motor, and internal wiring connections. No signs of frost, rust, or damage were observed, and the PVC condensate/venting, gas line connector, and surrounding ductwork appeared in good condition. System was left in proper working order with the access panel secured; filter was not supplied as part of this visit.
Performed seasonal heating tune-up on Carrier Infinity system, inspecting components and verifying operation with the thermostat. Found the humidifier water panel heavily coated with mineral scale and calcium buildup, which restricts evaporation and airflow, and recommended cleaning or replacement before the heating season.
Performed annual heating maintenance and inspected the blower assembly, finding the squirrel-cage wheel intact with only light dust accumulation and no signs of ice, rust, or cracks. Replaced the 16x25x1 and 20x25x4 filters per the recurring service schedule, and verified heating operation with a digital pocket thermometer, measuring a 101.1°F reading.
Responded to a service call for an audible clicking noise from the Lennox smart thermostat during scheduled-mode operation. Inspected the thermostat and wall-mounted subbase, noting an oversized, irregular wall opening behind the unit that leaves the thermostat mounted askew with gaps around its footprint, and verified display and schedule functions (heat-to/cool-to setpoints, mode, and indoor temperature readout) were operating normally. Recommend wall repair and a properly sized cover plate to secure the thermostat and eliminate the mounting-related noise.
Performed scheduled monthly heating maintenance, replacing the 16x20x1 air filter and inspecting the system for proper operation. Verified the water heater closet and adjacent utility area were accessible, with insulation, piping, and electrical connections in place and no visible leaks or abnormal conditions noted.
Performed scheduled heating maintenance on the air handler, including removal of the access panel and visual inspection of the blower assembly, control wiring, relays, transformer, and insulated refrigerant lines, with no frost, corrosion, or visible damage noted. Installed a new 20x30x2 pleated air filter with airflow direction verified, and reinstalled the access panel to restore the unit to normal operation.