Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in October 2026. The most recent job was on October 16, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Performed the follow-up repair to replace the hard start kit on the Daikin condenser unit. Accessed the outdoor unit's electrical compartment, inspected the dual-run capacitor, contactor, and control board wiring, and installed the new hard start kit to assist compressor startup. Verified the system was operating properly, with the thermostat calling for heat and the unit running normally.
Performed monthly heating maintenance inspection on the Carrier air handler/furnace and outdoor heat pump unit. Inspected the outdoor electrical control compartment, including the run capacitor, contactor, and wiring connections, and checked the indoor unit's condensate drain piping, ductwork, and accessory components for proper operation. System operating normally at completion; filter was not included in this visit.
Performed scheduled plumbing maintenance inspection, including a visual assessment of the tub/shower fixtures and the kitchen dishwasher installation. The tub spout, diverter lever, overflow cover, and pop-up drain were found clean and intact, with no evidence of leaks, corrosion, cracking, or buildup, and the dishwasher exterior showed no visible damage or rust. All inspected fixtures and drain components were in good working condition, and no repairs were required.
Installed two complete HVAC systems, including Lennox gas furnaces with air handlers, PVC condensate and venting, and wall-mounted touchscreen thermostat controls. Modified existing ductwork to accommodate the new equipment and installed a whole-home humidifier with associated plumbing and electrical connections. Completed all control wiring, conduit routing, and equipment labeling, and verified clean, organized installation with no visible damage.
Responded to a no-cool call on two rooftop systems and inspected both air-cooled condensing units, noting heavily soiled condenser coils and a severely corroded exterior electrical disconnect with weathered conduit and cabling running across the roof membrane. Documented the condition of the units and electrical components for further evaluation and repair recommendations.
Performed scheduled monthly heating maintenance on the air handler, inspecting the blower assembly, motor, and wiring connections and finding all in serviceable condition with only light dust accumulation. Inspected the evaporator coil and noted dust loading, a minor fin dent, and oxidation on the copper refrigerant lines, with no frost, ice, or heavy corrosion present. Filter replacement was not part of this visit, as the 20x25x4 filter was not included.
Performed a seasonal heat pump tune-up on a 9-year-old system, including a full operational check of heating mode and verification of thermostat function and calibration. Inspected the blower assembly and found significant dust and debris buildup on the blower wheel along with surface rust on the housing and wheel blades, which may reduce airflow and efficiency; recommend cleaning and monitoring the blower wheel and housing for further corrosion.
Replaced the failed pressure switch on the gas furnace with a new 1.65" WC rated unit, reconnecting the vacuum tubing and wiring harness. After installation, verified proper operation by confirming stable, blue burner flame and normal ignition sequence on a heating call. Noted moderate dust and lint buildup in the cabinet and around the inducer housing, recommending routine cleaning and maintenance.
Performed a seasonal heating maintenance inspection on the furnace system, including a basic annual filter check, and verified system operation. Measured supply air temperature at the plenum at 140°F, confirming proper heat output, and confirmed thermostat communication and operation on the Carrier Touch-N-Go control for Zone 1.
Performed seasonal heating maintenance and inspected the system, verifying thermostat operation and a successful call for heat on the ecobee smart thermostat. Serviced the air handler cabinet and replaced the 20x20x1 electronic air cleaning filter, and noted debris and microbial-type buildup along the cabinet lip and insulation edge, along with deteriorating foil-faced duct insulation near the filter access, which should be cleaned and repaired to maintain proper airflow and indoor air quality.
Performed scheduled heating system maintenance and inspected the air handler cabinet, confirming the evaporator coil fins are intact with no frost or ice buildup and no abnormal moisture accumulation. Verified the adjacent electric water heater and associated piping are in place, with no active leaks observed. Filter replacement was not included in this visit; system is operating normally.
Performed seasonal heating maintenance on the Lennox gas furnace, verifying proper operation in heat mode via the Honeywell ProSeries thermostat, which was calling for 75°F with the fan set to auto. Inspected the air handler cabinet, condensate drain piping, and foil-wrapped supply ductwork, and installed a new 16x20x4 pleated air filter to maintain airflow and system efficiency. The system was operating normally at completion, and the customer was advised that the maintenance membership is due for renewal.
Performed scheduled heating maintenance on the split-system heat pump, including replacement of the 20x20x4 return air filter and inspection of the vertical air handler, condensate drain line, and ductwork connections. Inspected the outdoor condensing unit's electrical section, including the run capacitor, contactor, and wiring terminations, and verified proper system operation in heating mode.
Performed annual heating maintenance on the gas furnace, removing the front panel to inspect the burner assembly, blower motor, and wiring. Conducted a combustion analysis with a UEi analyzer, recording O2 at 9.3%, CO2 at 6.6%, and CO at 6 ppm to verify safe, efficient operation. Combustion readings were within acceptable limits, with PVC venting intact and no visible damage noted.
Performed the second scheduled preventive maintenance visit for the residential HVAC system, including inspection of system operation and cooling mode functionality. Verified thermostat settings and operation, noting cooling mode active with indoor temperature reading in the high 70s, and documented the condition of the existing thermostats, including soiled housing and screen discoloration on the older unit. System was left operational and ready for continued seasonal use.
Performed A/C service and inspection, identifying oil staining and corrosion on the base pan at the copper line-to-fitting junction, indicating a probable refrigerant/oil leak at the joint. Documented the affected area and recommended leak testing and repair of the connection to restore system integrity.
Removed the existing toilet and found a heavily corroded toilet flange with old wax residue and debris around the drain opening. Cleaned the flange area and installed the customer-supplied toilets with new wax seals and closet bolts, then reconnected the water supply lines, tested for proper flush operation, and confirmed no leaks.
Performed scheduled monthly heating system maintenance, including replacement of the 20x25x1 air filter and verification of thermostat operation and system status. Borescope inspection of the coil revealed bent and dented fins along with signs of corrosion on adjacent components; recommend monitoring and follow-up evaluation to maintain optimal airflow and heat transfer efficiency.
Performed seasonal heating maintenance on the upflow gas furnace, inspecting the cabinet, access panels, PVC condensate/vent piping, and electrical connections for proper condition and operation. Verified thermostat function and system controls as part of the heating tune-up. The system was left in proper working order; the 16x25x4 media filter was not included in this visit.
Installed a complete Lennox heat pump system, including the vertical air handler in the utility closet with new refrigerant lines, condensate drain piping, and supply ductwork connections. Evacuated the refrigerant circuit to 151 microns with zero rise per minute, confirming a dry, leak-free system prior to refrigerant release and commissioning.