HVAC, Plumbing & Generators in Columbus, IN | Schedule Today

Expert HVAC, Plumbing & Generators in Columbus, IN

Backup generator outside of houseTaking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.

Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.

Schedule comprehensive home services in Columbus by calling (812) 372-8011 or contacting Reliable Comfort online.

Trusted Generators

When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:

  • Power for your HVAC system and refrigerator
  • Electricity for your computer and devices
  • Peace of mind that your home is safer

Install a reliable generator for your home. Call (812) 372-8011 to schedule an appointment in Columbus.

Reliable HVAC

Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:

  • Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
  • Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
  • Heating Maintenance: Look to us for comprehensive heating maintenance every year.
  • Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
  • Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.

Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:

  • Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
  • Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
  • Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
  • Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
  • Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.

No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.

Top-Rated Plumbing

At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.

Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 372-8011 to schedule plumbing services in Southern Indiana.

Why Choose Reliable Comfort?

For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.

For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 372-8011 to schedule.

FAQs

Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.

Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.

Recent Jobs and Reviews in Columbus, IN

Job Locations and Reviews

Replaced faulty outdoor thermostatic expansion valve (TXV) on Lennox unit to restore proper refrigerant metering and system performance. Verified thermostat operation and system functionality upon completion, with unit now maintaining proper heating and cooling capabilities.
Replaced faulty outdoor thermostatic expansion valve (TXV) on Lennox unit to restore proper refrigerant metering and system performance. Verified thermostat operation and system functionality upon completion, with unit now maintaining proper heating and cooling capabilities.
Balfret S.
Balfret S. Checked in
Replaced faulty outdoor thermostatic expansion valve (TXV) on Lennox unit to restore proper refrigerant metering and system performance. Verified thermostat operation and system functionality upon completion, with unit now maintaining proper heating and cooling capabilities.
Columbus, IN 47201
Columbus, IN - Responded to service call for frozen air conditioning unit. Upon arrival, found evaporator coil completely iced over, unit was already powered off to allow thawing process to begin. Inspected air handler compartment and documented conditions for further diagnostic evaluation once defrost cycle completes.
Daniel R.
Daniel R. Checked in
Responded to service call for frozen air conditioning unit. Upon arrival, found evaporator coil completely iced over, unit was already powered off to allow thawing process to begin. Inspected air handler compartment and documented conditions for further diagnostic evaluation once defrost cycle completes.
Columbus, IN 47203
Columbus, IN - Responded to no-cooling complaint on residential air conditioning system. Diagnosed system failure to start and identified issue preventing unit operation. Restored cooling functionality and verified proper system operation upon completion.
Daniel R.
Daniel R. Checked in
Responded to no-cooling complaint on residential air conditioning system. Diagnosed system failure to start and identified issue preventing unit operation. Restored cooling functionality and verified proper system operation upon completion.
Columbus, IN 47201
Columbus, IN - Completed routine cooling maintenance on Carrier system. Performed standard inspection and servicing procedures. Thermostat displayed filter check alert at time of service; customer has active maintenance agreement renewing 9/28/26 with 20x20x4 filter size not included in coverage.
Dustin B.
Dustin B. Checked in
Completed routine cooling maintenance on Carrier system. Performed standard inspection and servicing procedures. Thermostat displayed filter check alert at time of service; customer has active maintenance agreement renewing 9/28/26 with 20x20x4 filter size not included in coverage.
Columbus, IN 47203
Responded to no cooling complaint on central air conditioning system. Upon arrival, found refrigerant lines frozen at outdoor unit, indicating low refrigerant charge or restricted airflow. Inspected indoor evaporator coil and ductwork, noting 16x20x1 filter size and some discoloration on insulation components. Connected Fieldpiece SMAN manifold gauges to service ports and recorded system pressures and temperatures. Suction pressure reading of 133 PSI and discharge pressure of 413 PSI confirmed abnormal operating conditions. Diagnosed low refrigerant charge as primary cause of freezing and loss of cooling capacity. Allowed system to thaw completely before proceeding with repairs. Located and repaired refrigerant leak, then evacuated system to proper vacuum levels. Recharged system to manufacturer specifications and verified proper operation. Monitored system performance until pressures stabilized and confirmed adequate cooling output. Replaced air filter and advised on proper maintenanc
Responded to no cooling complaint on central air conditioning system. Upon arrival, found refrigerant lines frozen at outdoor unit, indicating low refrigerant charge or restricted airflow. Inspected indoor evaporator coil and ductwork, noting 16x20x1 filter size and some discoloration on insulation components. Connected Fieldpiece SMAN manifold gauges to service ports and recorded system pressures and temperatures. Suction pressure reading of 133 PSI and discharge pressure of 413 PSI confirmed abnormal operating conditions. Diagnosed low refrigerant charge as primary cause of freezing and loss of cooling capacity. Allowed system to thaw completely before proceeding with repairs. Located and repaired refrigerant leak, then evacuated system to proper vacuum levels. Recharged system to manufacturer specifications and verified proper operation. Monitored system performance until pressures stabilized and confirmed adequate cooling output. Replaced air filter and advised on proper maintenanc
Daniel R.
Daniel R. Checked in
Responded to no cooling complaint on central air conditioning system. Upon arrival, found refrigerant lines frozen at outdoor unit, indicating low refrigerant charge or restricted airflow. Inspected indoor evaporator coil and ductwork, noting 16x20x1 filter size and some discoloration on insulation components. Connected Fieldpiece SMAN manifold gauges to service ports and recorded system pressures and temperatures. Suction pressure reading of 133 PSI and discharge pressure of 413 PSI confirmed abnormal operating conditions. Diagnosed low refrigerant charge as primary cause of freezing and loss of cooling capacity. Allowed system to thaw completely before proceeding with repairs. Located and repaired refrigerant leak, then evacuated system to proper vacuum levels. Recharged system to manufacturer specifications and verified proper operation. Monitored system performance until pressures stabilized and confirmed adequate cooling output. Replaced air filter and advised on proper maintenanc
Columbus, IN 47201
Completed basic monthly cooling maintenance on three-system property. Performed standard preventive maintenance procedures including inspection of mechanical components, refrigerant lines, and electrical connections. Installed one 14x20x1 filter as included in maintenance agreement; customer responsible for 16x20x4 filter replacement. Verified thermostat operation showing proper temperature control at 64°F setpoint. All systems inspected and found operating within normal parameters with no deficiencies noted at time of service.
Completed basic monthly cooling maintenance on three-system property. Performed standard preventive maintenance procedures including inspection of mechanical components, refrigerant lines, and electrical connections. Installed one 14x20x1 filter as included in maintenance agreement; customer responsible for 16x20x4 filter replacement. Verified thermostat operation showing proper temperature control at 64°F setpoint. All systems inspected and found operating within normal parameters with no deficiencies noted at time of service.
Clayton C.
Clayton C. Checked in
Completed basic monthly cooling maintenance on three-system property. Performed standard preventive maintenance procedures including inspection of mechanical components, refrigerant lines, and electrical connections. Installed one 14x20x1 filter as included in maintenance agreement; customer responsible for 16x20x4 filter replacement. Verified thermostat operation showing proper temperature control at 64°F setpoint. All systems inspected and found operating within normal parameters with no deficiencies noted at time of service.
Columbus, IN 47201
Completed comprehensive cooling maintenance on Goodman HVAC system. Performed CCC basic monthly service protocol, which included inspecting and replacing 16x25x1 air filter, checking thermostat operation (ecobee unit displaying proper cooling mode at 75°F setpoint), and evaluating overall system performance. Verified furnace unit condition, condensate drainage system, and associated ductwork for proper operation during cooling season.
Completed comprehensive cooling maintenance on Goodman HVAC system. Performed CCC basic monthly service protocol, which included inspecting and replacing 16x25x1 air filter, checking thermostat operation (ecobee unit displaying proper cooling mode at 75°F setpoint), and evaluating overall system performance. Verified furnace unit condition, condensate drainage system, and associated ductwork for proper operation during cooling season.
Dustin B.
Dustin B. Checked in
Completed comprehensive cooling maintenance on Goodman HVAC system. Performed CCC basic monthly service protocol, which included inspecting and replacing 16x25x1 air filter, checking thermostat operation (ecobee unit displaying proper cooling mode at 75°F setpoint), and evaluating overall system performance. Verified furnace unit condition, condensate drainage system, and associated ductwork for proper operation during cooling season.
Columbus, IN 47201
Completed monthly HVAC maintenance visit including comprehensive cooling system inspection. Performed visual inspection of outdoor condensing unit, checking electrical connections, capacitor, and wiring integrity. Inspected indoor furnace unit and ductwork system in basement mechanical area. Replaced 16x25x1 air filter as part of routine maintenance service. All system components operating within normal parameters with no issues identified during inspection.
Completed monthly HVAC maintenance visit including comprehensive cooling system inspection. Performed visual inspection of outdoor condensing unit, checking electrical connections, capacitor, and wiring integrity. Inspected indoor furnace unit and ductwork system in basement mechanical area. Replaced 16x25x1 air filter as part of routine maintenance service. All system components operating within normal parameters with no issues identified during inspection.
Dorian M.
Dorian M. Checked in
Completed monthly HVAC maintenance visit including comprehensive cooling system inspection. Performed visual inspection of outdoor condensing unit, checking electrical connections, capacitor, and wiring integrity. Inspected indoor furnace unit and ductwork system in basement mechanical area. Replaced 16x25x1 air filter as part of routine maintenance service. All system components operating within normal parameters with no issues identified during inspection.
Columbus, IN 47203
Responded to service call for TF 79 unit experiencing excessive condensation and water leakage into pool room. Inspected air handler unit and condensate drainage system. Found condensate drain line issue causing water overflow. Cleared blockage in condensate drain line, verified proper drainage flow, and tested system operation to ensure condensate was being properly evacuated from the unit without further leakage.
Responded to service call for TF 79 unit experiencing excessive condensation and water leakage into pool room. Inspected air handler unit and condensate drainage system. Found condensate drain line issue causing water overflow. Cleared blockage in condensate drain line, verified proper drainage flow, and tested system operation to ensure condensate was being properly evacuated from the unit without further leakage.
Daniel R.
Daniel R. Checked in
Responded to service call for TF 79 unit experiencing excessive condensation and water leakage into pool room. Inspected air handler unit and condensate drainage system. Found condensate drain line issue causing water overflow. Cleared blockage in condensate drain line, verified proper drainage flow, and tested system operation to ensure condensate was being properly evacuated from the unit without further leakage.
Columbus, IN 47201
Completed installation of Lennox air conditioning system with matching evaporator coil. New outdoor condenser unit positioned on protective pad with gravel base, electrical disconnect box mounted to exterior wall with proper conduit routing and connections. System tested and verified operational with temperature readings confirming proper cooling performance.
Completed installation of Lennox air conditioning system with matching evaporator coil. New outdoor condenser unit positioned on protective pad with gravel base, electrical disconnect box mounted to exterior wall with proper conduit routing and connections. System tested and verified operational with temperature readings confirming proper cooling performance.
Carl B.
Carl B. Checked in
Completed installation of Lennox air conditioning system with matching evaporator coil. New outdoor condenser unit positioned on protective pad with gravel base, electrical disconnect box mounted to exterior wall with proper conduit routing and connections. System tested and verified operational with temperature readings confirming proper cooling performance.
Columbus, IN 47201
Completed comprehensive cooling maintenance service as part of basic monthly preventative maintenance agreement. Performed standard system inspection of Lennox furnace and cooling components, replaced 20x25x1 air filter, and verified proper operation of Nest thermostat currently set to heat to 76°F. All equipment operating within normal parameters with no deficiencies noted.
Completed comprehensive cooling maintenance service as part of basic monthly preventative maintenance agreement. Performed standard system inspection of Lennox furnace and cooling components, replaced 20x25x1 air filter, and verified proper operation of Nest thermostat currently set to heat to 76°F. All equipment operating within normal parameters with no deficiencies noted.
Dustin B.
Dustin B. Checked in
Completed comprehensive cooling maintenance service as part of basic monthly preventative maintenance agreement. Performed standard system inspection of Lennox furnace and cooling components, replaced 20x25x1 air filter, and verified proper operation of Nest thermostat currently set to heat to 76°F. All equipment operating within normal parameters with no deficiencies noted.
Columbus, IN 47203
Completed Basic Cooling Visit - Monthly recurring service on Carrier air conditioning system. Performed standard maintenance inspection of outdoor condenser unit and verified thermostat operation at 70.5°F. Connected diagnostic gauges to service ports and tested system performance parameters. Customer will require follow-up visit for blower cleaning and filter replacement (20x20x4 media filter not included in this service).
Completed Basic Cooling Visit - Monthly recurring service on Carrier air conditioning system. Performed standard maintenance inspection of outdoor condenser unit and verified thermostat operation at 70.5°F. Connected diagnostic gauges to service ports and tested system performance parameters. Customer will require follow-up visit for blower cleaning and filter replacement (20x20x4 media filter not included in this service).
Dorian M.
Dorian M. Checked in
Completed Basic Cooling Visit - Monthly recurring service on Carrier air conditioning system. Performed standard maintenance inspection of outdoor condenser unit and verified thermostat operation at 70.5°F. Connected diagnostic gauges to service ports and tested system performance parameters. Customer will require follow-up visit for blower cleaning and filter replacement (20x20x4 media filter not included in this service).
Columbus, IN 47201
Completed basic monthly cooling maintenance visit on residential HVAC system. Performed standard inspection of cooling equipment, verified thermostat operation displaying 72°F, and checked system controls and settings. All components found operating within normal parameters with no issues identified during this routine preventative maintenance service.
Completed basic monthly cooling maintenance visit on residential HVAC system. Performed standard inspection of cooling equipment, verified thermostat operation displaying 72°F, and checked system controls and settings. All components found operating within normal parameters with no issues identified during this routine preventative maintenance service.
Dustin B.
Dustin B. Checked in
Completed basic monthly cooling maintenance visit on residential HVAC system. Performed standard inspection of cooling equipment, verified thermostat operation displaying 72°F, and checked system controls and settings. All components found operating within normal parameters with no issues identified during this routine preventative maintenance service.
Columbus, IN 47203
Completed comprehensive cooling maintenance on Lennox outdoor condensing unit. Performed standard preventive maintenance procedures including inspection of condenser coil, fan motor operation, and refrigerant lines. Verified thermostat functionality with unit responding properly to cooling calls and maintaining setpoint of 73°F. Checked electrical connections, contactor operation, and capacitor values. Inspected condensate drainage system for proper flow. Unit operating within normal parameters with adequate airflow through condenser coil. Customer advised that 20x25x4 filter replacement not included in this service visit and should be replaced separately per their filter maintenance schedule.
Completed comprehensive cooling maintenance on Lennox outdoor condensing unit. Performed standard preventive maintenance procedures including inspection of condenser coil, fan motor operation, and refrigerant lines. Verified thermostat functionality with unit responding properly to cooling calls and maintaining setpoint of 73°F. Checked electrical connections, contactor operation, and capacitor values. Inspected condensate drainage system for proper flow. Unit operating within normal parameters with adequate airflow through condenser coil. Customer advised that 20x25x4 filter replacement not included in this service visit and should be replaced separately per their filter maintenance schedule.
Zach L.
Zach L. Checked in
Completed comprehensive cooling maintenance on Lennox outdoor condensing unit. Performed standard preventive maintenance procedures including inspection of condenser coil, fan motor operation, and refrigerant lines. Verified thermostat functionality with unit responding properly to cooling calls and maintaining setpoint of 73°F. Checked electrical connections, contactor operation, and capacitor values. Inspected condensate drainage system for proper flow. Unit operating within normal parameters with adequate airflow through condenser coil. Customer advised that 20x25x4 filter replacement not included in this service visit and should be replaced separately per their filter maintenance schedule.
Columbus, IN 47203
Responded to no cooling complaint and performed troubleshooting on split system air conditioning unit. Inspected exterior disconnect box and found accumulated debris, dust buildup, and aged fuse assembly with visible wear on terminals and connections. Examined indoor air handler unit with front access panel removed, revealing internal electrical components, control board, and wiring connections requiring attention to restore proper operation.
Responded to no cooling complaint and performed troubleshooting on split system air conditioning unit. Inspected exterior disconnect box and found accumulated debris, dust buildup, and aged fuse assembly with visible wear on terminals and connections. Examined indoor air handler unit with front access panel removed, revealing internal electrical components, control board, and wiring connections requiring attention to restore proper operation.
Daniel R.
Daniel R. Checked in
Responded to no cooling complaint and performed troubleshooting on split system air conditioning unit. Inspected exterior disconnect box and found accumulated debris, dust buildup, and aged fuse assembly with visible wear on terminals and connections. Examined indoor air handler unit with front access panel removed, revealing internal electrical components, control board, and wiring connections requiring attention to restore proper operation.
Columbus, IN 47201
Completed basic monthly cooling maintenance visit on Carrier HVAC system. Performed standard inspection of indoor furnace unit and outdoor condensing unit, verified proper operation of electrical components including MARS capacitor, checked refrigerant connections, and inspected all accessible system components. System operating within normal parameters with no deficiencies noted at time of service.
Completed basic monthly cooling maintenance visit on Carrier HVAC system. Performed standard inspection of indoor furnace unit and outdoor condensing unit, verified proper operation of electrical components including MARS capacitor, checked refrigerant connections, and inspected all accessible system components. System operating within normal parameters with no deficiencies noted at time of service.
Dustin B.
Dustin B. Checked in
Completed basic monthly cooling maintenance visit on Carrier HVAC system. Performed standard inspection of indoor furnace unit and outdoor condensing unit, verified proper operation of electrical components including MARS capacitor, checked refrigerant connections, and inspected all accessible system components. System operating within normal parameters with no deficiencies noted at time of service.
Columbus, IN 47203
Completed prepaid plumbing inspection of residential property, coordinating timing with HVAC service between 10-12. Inspected and documented water supply line installation in utility closet, including blue PVC piping with orange ball valve shut-off and brass compression fittings. Examined bathroom plumbing fixtures including bathtub with chrome single-handle faucet assembly, tub spout, and drain. All components photographed for record. No immediate repairs required at time of inspection.
Completed prepaid plumbing inspection of residential property, coordinating timing with HVAC service between 10-12. Inspected and documented water supply line installation in utility closet, including blue PVC piping with orange ball valve shut-off and brass compression fittings. Examined bathroom plumbing fixtures including bathtub with chrome single-handle faucet assembly, tub spout, and drain. All components photographed for record. No immediate repairs required at time of inspection.
Ryan C.
Ryan C. Checked in
Completed prepaid plumbing inspection of residential property, coordinating timing with HVAC service between 10-12. Inspected and documented water supply line installation in utility closet, including blue PVC piping with orange ball valve shut-off and brass compression fittings. Examined bathroom plumbing fixtures including bathtub with chrome single-handle faucet assembly, tub spout, and drain. All components photographed for record. No immediate repairs required at time of inspection.
Columbus, IN 47203
Responded to emergency call for hot water leak from recently installed temperature and pressure relief valve on A.O. Smith Signature 100 water heater. Upon arrival, found T&P relief valve had discharged, causing water intrusion into basement area. Inspected water heater installation, including copper supply piping, inlet/outlet connections, expansion tank with brass fittings and corrugated flexible connector, and T&P relief valve discharge pipe. Assessed system pressure and temperature conditions to determine cause of valve activation. Replaced faulty temperature and pressure relief valve and verified proper operation of expansion tank to prevent excessive system pressure buildup. Tested all connections for leaks, confirmed proper water flow restoration, and verified system returned to normal operating parameters with no further discharge occurring.
Responded to emergency call for hot water leak from recently installed temperature and pressure relief valve on A.O. Smith Signature 100 water heater. Upon arrival, found T&P relief valve had discharged, causing water intrusion into basement area. Inspected water heater installation, including copper supply piping, inlet/outlet connections, expansion tank with brass fittings and corrugated flexible connector, and T&P relief valve discharge pipe. Assessed system pressure and temperature conditions to determine cause of valve activation. Replaced faulty temperature and pressure relief valve and verified proper operation of expansion tank to prevent excessive system pressure buildup. Tested all connections for leaks, confirmed proper water flow restoration, and verified system returned to normal operating parameters with no further discharge occurring.
Ryan C.
Ryan C. Checked in
Responded to emergency call for hot water leak from recently installed temperature and pressure relief valve on A.O. Smith Signature 100 water heater. Upon arrival, found T&P relief valve had discharged, causing water intrusion into basement area. Inspected water heater installation, including copper supply piping, inlet/outlet connections, expansion tank with brass fittings and corrugated flexible connector, and T&P relief valve discharge pipe. Assessed system pressure and temperature conditions to determine cause of valve activation. Replaced faulty temperature and pressure relief valve and verified proper operation of expansion tank to prevent excessive system pressure buildup. Tested all connections for leaks, confirmed proper water flow restoration, and verified system returned to normal operating parameters with no further discharge occurring.
Columbus, IN 47201
Columbus, IN - Responded to service call for leaking basket strainer on left-hand sink drain. Upon inspection, determined the basket strainer previously replaced required resealing due to compromised seal integrity. Successfully removed and reinstalled basket strainer with new plumber's putty and gasket to eliminate leak at sink mounting point.
Brad D.
Brad D. Checked in
Responded to service call for leaking basket strainer on left-hand sink drain. Upon inspection, determined the basket strainer previously replaced required resealing due to compromised seal integrity. Successfully removed and reinstalled basket strainer with new plumber's putty and gasket to eliminate leak at sink mounting point.
Columbus, IN 47201
Responded to geothermal system failure with yellow and red indicator lights flashing, specifically high pressure alarm activated after customer returned from vacation and attempted system reset. Performed diagnostic pressure testing on refrigerant circuit using calibrated gauges, documenting readings at multiple test points to identify high pressure condition. System requires valve caps replacement as previously noted; recommend addressing during scheduled maintenance appointment.
Responded to geothermal system failure with yellow and red indicator lights flashing, specifically high pressure alarm activated after customer returned from vacation and attempted system reset. Performed diagnostic pressure testing on refrigerant circuit using calibrated gauges, documenting readings at multiple test points to identify high pressure condition. System requires valve caps replacement as previously noted; recommend addressing during scheduled maintenance appointment.
Daniel R.
Daniel R. Checked in
Responded to geothermal system failure with yellow and red indicator lights flashing, specifically high pressure alarm activated after customer returned from vacation and attempted system reset. Performed diagnostic pressure testing on refrigerant circuit using calibrated gauges, documenting readings at multiple test points to identify high pressure condition. System requires valve caps replacement as previously noted; recommend addressing during scheduled maintenance appointment.
Columbus, IN 47201

Discover the Difference

Family Operated

Our family’s dedication to world- class customer service has helped us expand from a one-truck operation to a close-knit team of HVAC, plumbing and electrical experts.

Satisfaction Guaranteed

We back all our services with a 100% satisfaction guarantee for your peace of mind.

A+ BBB Rating

Our excellent track record of quality service and happy customers has earned us a consistent A+ rating from the Better Business Bureau.

All Brands Serviced

You never have to worry whether Reliable Comfort can provide service because we work with all HVAC and plumbing equipment brands.

Online Specials

To make repair, maintenance, and installation more accessible, we offer a variety of online specials for discounts on whatever services you may need.

Emergency Services

HVAC and plumbing emergencies can be nerve-racking. Reliable Comfort offers emergency services to fix sudden problems fast.

Family Operated

Our family’s dedication to world- class customer service has helped us expand from a one-truck operation to a close-knit team of HVAC, plumbing and electrical experts.

Satisfaction Guaranteed

We back all our services with a 100% satisfaction guarantee for your peace of mind.

A+ BBB Rating

Our excellent track record of quality service and happy customers has earned us a consistent A+ rating from the Better Business Bureau.

All Brands Serviced

You never have to worry whether Reliable Comfort can provide service because we work with all HVAC and plumbing equipment brands.

Online Specials

To make repair, maintenance, and installation more accessible, we offer a variety of online specials for discounts on whatever services you may need.

Emergency Services

HVAC and plumbing emergencies can be nerve-racking. Reliable Comfort offers emergency services to fix sudden problems fast.

Our Reviews

What Our Clients Are Saying

I can’t say enough good things about this company, they truly do live up to their name: RELIABLE!

S. Mahoney

I have health issues that make it fatal to be in hot temperatures for very long. My AC unit broke down (the motor and the starting component, I believe) in the middle of the night, and with high temperatures expected the next day, I was really…really scared. I called this company and they were extremely understanding.…

C. Abner

We have been long time customers of Reliable Comfort. We prefer doing business with a family owned/managed enterprise. Office staff are always personable and efficient. Service technicians are on time, knowledgeable and thorough. We recommend Reliable Comfort to our friends and neighbors.

J. Kerns

Just had a full duct cleaning and sealing job on my Carrier HP System by Cody, Logan, and Justin. The guys were great – very professional, very nice and polite, and very careful not to disturb or damage any of my wife’s Christmas decorations in the house. All in all, the process went very well, reducing…

T. Parsons

I have relied on Reliable Comfort for my furnace/AC needs for 10 years and have always found the technicians to be knowledgeable and kind to work with. They never try to push any new products, but do make an effort to keep me informed about what’s available.

W. Artist