Taking care of your home’s essential systems is a breeze with the right team on the job. Reliable Comfort is here to make sure you’re comfortable in your home.
Our team has the tools and talents to diagnose and resolve problems with your HVAC, plumbing, and electrical systems. We’ll discuss your needs and perform the most necessary repairs or replacements. We’re highly rated for our services and work hard to meet your needs.
Schedule comprehensive home services in Columbus by calling (812) 200-0786 or contacting Reliable Comfort online.
Trusted Generators
When the power goes out, will you have electricity? Make sure you’re ready with a whole-home generator. Our team installs standby systems that automatically turn on when needed. When you have a generator for your home, you can enjoy:
- Power for your HVAC system and refrigerator
- Electricity for your computer and devices
- Peace of mind that your home is safer
Install a reliable generator for your home. Call (812) 200-0786 to schedule an appointment in Columbus.
Reliable HVAC
Heat is essential for your Columbus-area home. With Reliable Comfort, you can expect top-quality heating services for your property. Count on us for:
- Heating Repair: We can repair motors, electrical connections, heating elements, and much more.
- Heating Replacement: Our team can replace your old heating unit with a new, energy-efficient one.
- Heating Maintenance: Look to us for comprehensive heating maintenance every year.
- Furnaces: We work on all brands of furnaces and can repair, install, or maintain these systems.
- Boilers: Our team has years of experience handling boiler system problems and will ensure yours is in great condition.
Keeping cool is just as important for homeowners in Columbus. Count on our team when you need:
- Cooling Repair: Our team can repair your condenser coil, blower motor, and various other essential parts.
- Cooling Replacement: We can remove your old AC unit and install a new one that will last for years.
- Cooling Maintenance: Annual AC maintenance can add years to your system and lower energy bills.
- Heat Pumps: Rely on us when you need heat pump services for your heating and cooling unit.
- Ductless Mini-Splits: We can ensure your units stay in great shape if you rely on mini-splits to heat or cool certain rooms.
No matter your heating or cooling needs, Reliable Comfort is your reliable team for the job.
Top-Rated Plumbing
At Reliable Comfort, we do more than just HVAC service — we also provide plumbing repairs and replacements. Our team can discuss your plumbing issues and provide solutions that fit your needs. From water heaters to drains and more, we’re your go-to team for comprehensive plumbing services.
Leave your plumbing needs to a team of professional plumbers. Contact us online or call (812) 200-0786 to schedule plumbing services in Southern Indiana.
Why Choose Reliable Comfort?
For over 20 years, our team has been resolving HVAC issues of all types throughout Columbus, IN. Our family-operated business treats everyone like family. We believe in top-tier maintenance plans, upfront pricing, specials, warranties, and providing 100% satisfaction, guaranteed.
For expert home services in Columbus, look no further than Reliable Comfort. Reach us online or call (812) 200-0786 to schedule.
FAQs
Why does it smell bad when my heat comes on?
Several problems could be causing a bad smell when you run your heat. But the most common issue is a buildup of dust that had time to collect throughout the year while the furnace was not in use.
Are geothermal HVAC systems good for Indiana homes?
Yes! These systems use the Earth’s temperature to heat or cool your home, and our area has temperate land. They’re an excellent energy-efficient option for this climate.
Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 20 jobs in Columbus, IN in November 2026. The most recent job was on November 13, 2026. Reliable Comfort Heating, Air Conditioning, & Plumbing has completed 3,660 jobs in Columbus, IN in the last 12 months.Recent Jobs and Reviews in Columbus, IN
Columbus, IN at a glance
Job Locations and Reviews
Performed annual plumbing inspection, including examination of the toilet supply line and chrome angle-stop shutoff valve, where discoloration and possible moisture staining were observed on the adjacent flooring, indicating a potential slow leak that should be monitored or further evaluated. Inspected PVC drain and condensate piping at the mechanical equipment, noting yellowish-brown staining and residue at the rubber coupling connections that may indicate seepage and warrants follow-up evaluation.
Replaced the existing commercial toilet in an ADA-accessible restroom stall with a new white two-piece elongated bowl, open-front seat, and chrome flush lever. Removed the old fixture, installed a new wax ring and closet bolts, secured the bowl to the flange, and reconnected the water supply. Tested for proper flush operation and verified there were no leaks at the base or supply connection.
Responded to a no-heat complaint on the upper level of a multi-zone residence with hydronic boiler heating alongside two gas and one electric system. Inspected the Emerson thermostat controlling the affected zone and identified a low-battery warning with erratic setpoint and temperature readings, which was preventing a reliable call for heat. Recommended battery replacement to restore proper thermostat operation and zone heating.
Performed scheduled heating system maintenance, including a combustion analysis with a UEi C161 analyzer to verify flue gas readings and combustion efficiency, and inspected the surrounding mechanical equipment, flue piping, and drain pans for leaks, corrosion, and visible anomalies. No deficiencies were identified, and the system was found in satisfactory operating condition. The filter (20x25x5) was not included in this visit.
Performed seasonal heating maintenance on the gas furnace, inspecting the burner assembly, gas valve, and pressure switch and confirming a stable flame with proper ignition and operation. Installed a new 20x25x4 filter and verified wiring connections and the general condition of the equipment, with no signs of damage or abnormal wear noted.
Completed the installation of discharge lines from the geothermal system to the dry well, trenching and laying flexible black poly pipe and securing the connection to a rigid pipe section with double hose clamps. The line terminates at a vertical riser fitting, and all excavated areas were left backfilled and graded.
Inspected two wall-mounted analog line-voltage thermostats controlling the electric baseboard heating zones and confirmed both heating circuits were operating. Both rotary-dial units were aged and worn, and replacement of the thermostats was recommended to ensure reliable temperature control.
Performed scheduled monthly heating maintenance on two central heating units, verifying thermostat operation (room temperature reading 68°) and conducting combustion analysis on natural gas with a Bacharach analyzer, recording O2 at 7.2% and CO at 25 ppm. Systems were inspected for proper operation; the 20x20x4 filters were not supplied as part of this service.
Responded to a no-heat call on a heat pump with a non-operational blower and suspected loss of power to the unit. Inspected the air handler and found the cabinet interior and insulated lining heavily soiled, with visible debris buildup, suspected microbial growth, and surface corrosion along the cabinet edges. Documented the equipment condition and data plate information, and noted that the installed unit does not match the brand and install date on file, so records need updating. The power supply and blower circuit diagnosis and repair were not documented in the available service details, so the unit's operating status and any further work required should be verified.
Returned to locate an R-32 refrigerant leak on a multi-head mini-split system by pressurizing each indoor head, the individual outdoor line sets, and all indoor and outdoor connections for leak detection. Opened and partially disassembled the outdoor condenser unit to access the coil, service valves, and line set connections, and noted heavy dirt and debris buildup on the base pan.
Performed scheduled monthly heating maintenance on two central heating units, including a visual inspection of components, verification of proper heating-cycle operation, and a check of thermostat response and airflow. The 20x25x4 filters were not supplied for this visit. Both systems were left operating normally.
Completed annual heating maintenance on a Carrier gas furnace, inspecting the cabinet and vent panel and confirming normal burner operation with no signs of frost, rust, or damage. Verified the 20x25x4 Filtrete air filter is installed and seated properly in its slot above the furnace, and tested the Carrier digital thermostat in heat mode at a 70° setpoint to confirm proper call for heat and system response.
Performed scheduled heating system maintenance on a Carrier air handler, including inspection of the unit, controls, wiring, refrigerant lines, and condensate drain connection, and verified temperature readings at the access panel. Supplied and installed a new 20x20x4 filter as requested, and noted no signs of frost, rust, or visible damage, with the system operating normally at completion.
Performed an on-site evaluation for a standby generator installation, documenting the exterior utility service entrance including the electric meter, the natural gas meter and regulator assembly, and the available clearance along the rear wall for equipment placement. Inspected the main electrical panel located in the garage, noting its accessible recessed mounting, and confirmed no visible damage, corrosion, or unusual conditions at the meters or piping. Findings were recorded to support generator sizing, transfer switch placement, and gas supply planning for the proposed installation.
Responded to a no-heat call on a Lennox ML196UH070 gas furnace with a recently replaced blower motor and control board. Inspected the thermostat, which showed a blank display with no power, and used a dual-port digital manometer to check static pressure and draft readings on the ductwork and furnace. The unit remains non-operational; further diagnostics are needed to isolate the root cause, with the thermostat power supply and the recently installed components as the primary areas of concern.
Responded to a complaint of abnormal furnace operation, including an unusual shutdown noise and 2-3 short on/off cycles, and performed a diagnostic inspection of the air handler, thermostat, condensate drain, and refrigerant line set. The unit and controls showed no visible frost, ice, rust, or damage, the condensate drain and insulated suction line were intact, and the thermostat was operating normally in Heat mode with Fan on Auto, calling for and holding the 70° set point.
Performed an on-site assessment to verify clearance and height restrictions for equipment placement, using a tape measure to document the cabinet dimensions of the air handler and the surrounding structural clearances. Measurements were recorded and photographed to confirm the unit fits within the available space and to support equipment sizing and installation planning.
Performed a routine maintenance tune-up on a 4-year-old Goodman gas furnace, inspecting the blower assembly and confirming the blower wheel was clean, free of corrosion, and in good condition. Verified thermostat operation and calibration, and the system was found to be operating properly with no deficiencies noted.
Inspected the dryer vent run in the ceiling cavity and found a damaged section of flexible aluminum duct at the elbow transition, with deteriorated tape and a clamp connection. Replaced the damaged section with a new 4-inch elbow, secured the connections with screws, and sealed the joints with foil tape to restore proper exhaust airflow.
Inspected the HVAC air handler electrical connections and breaker panel in response to the concern of improperly installed wiring. Found evidence of overheating and arcing, including scorched, charred debris and discolored insulation in the cabinet, along with heavily taped, worn conductors near the 60A breakers. Recommended replacing the damaged wiring and affected components, cleaning out the burnt debris, and re-terminating the circuit to code before the unit is returned to service.